Mohamed Aboughanima, Abdelhameed Elsayed, Amr A. Arafat
{"title":"主动脉内球囊泵的罕见并发症","authors":"Mohamed Aboughanima, Abdelhameed Elsayed, Amr A. Arafat","doi":"10.4103/sccj.sccj_28_22","DOIUrl":null,"url":null,"abstract":"Intra-aortic balloon pump (IABP) is commonly used for circulatory support in patients with cardiogenic shock. IABP is associated with several complications; however, IABP rupture was rarely reported. We present a female patient with acute myocardial infarction and ventricular septal rupture. The patient underwent transcatheter device closure of the ventricular septum and IABP insertion. After 4 days of insertion, we encountered a failure to cycle alarm. The IABP was removed with difficulty, and a leak coming from the shaft near the bifurcation was found. This case highlighted the importance of early detection of IABP rupture to avoid entrapment and further complications.","PeriodicalId":345799,"journal":{"name":"Saudi Critical Care Journal","volume":"384 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A rare complication of intra-aortic balloon pump\",\"authors\":\"Mohamed Aboughanima, Abdelhameed Elsayed, Amr A. Arafat\",\"doi\":\"10.4103/sccj.sccj_28_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Intra-aortic balloon pump (IABP) is commonly used for circulatory support in patients with cardiogenic shock. IABP is associated with several complications; however, IABP rupture was rarely reported. We present a female patient with acute myocardial infarction and ventricular septal rupture. The patient underwent transcatheter device closure of the ventricular septum and IABP insertion. After 4 days of insertion, we encountered a failure to cycle alarm. The IABP was removed with difficulty, and a leak coming from the shaft near the bifurcation was found. This case highlighted the importance of early detection of IABP rupture to avoid entrapment and further complications.\",\"PeriodicalId\":345799,\"journal\":{\"name\":\"Saudi Critical Care Journal\",\"volume\":\"384 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Saudi Critical Care Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/sccj.sccj_28_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Saudi Critical Care Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/sccj.sccj_28_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Intra-aortic balloon pump (IABP) is commonly used for circulatory support in patients with cardiogenic shock. IABP is associated with several complications; however, IABP rupture was rarely reported. We present a female patient with acute myocardial infarction and ventricular septal rupture. The patient underwent transcatheter device closure of the ventricular septum and IABP insertion. After 4 days of insertion, we encountered a failure to cycle alarm. The IABP was removed with difficulty, and a leak coming from the shaft near the bifurcation was found. This case highlighted the importance of early detection of IABP rupture to avoid entrapment and further complications.