{"title":"流量传感器中脉冲导线和热流系统的信号特性","authors":"O. Ecin, R. Viga, B. Hosticka, A. Grabmaier","doi":"10.1109/ECCTD.2011.6043374","DOIUrl":null,"url":null,"abstract":"This article describes a pulsed thermal Time-of-Flight (TTOF) flow sensor system as two subsystems i.e., a pulsed-wire system and a heat flow system. The entire flow sensor is regarded system-theoretically as a linear time-invariant (LTI) system and is described by its transfer function or impulse response. The characterization of the thermo-fluid dynamic signals obtained by a pulsed-wire and by a heat flow is strived. Hence, the impulse response of both pulsed-wire and heat flow is analyzed according to the flow velocity. Experimental and theoretical results are compared in a flow velocity range in air between 0.1 m/s and 1.4 m/s.","PeriodicalId":126960,"journal":{"name":"2011 20th European Conference on Circuit Theory and Design (ECCTD)","volume":"412 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Signal characterization of a pulsed-wire and heat flow system at a flow sensor\",\"authors\":\"O. Ecin, R. Viga, B. Hosticka, A. Grabmaier\",\"doi\":\"10.1109/ECCTD.2011.6043374\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article describes a pulsed thermal Time-of-Flight (TTOF) flow sensor system as two subsystems i.e., a pulsed-wire system and a heat flow system. The entire flow sensor is regarded system-theoretically as a linear time-invariant (LTI) system and is described by its transfer function or impulse response. The characterization of the thermo-fluid dynamic signals obtained by a pulsed-wire and by a heat flow is strived. Hence, the impulse response of both pulsed-wire and heat flow is analyzed according to the flow velocity. Experimental and theoretical results are compared in a flow velocity range in air between 0.1 m/s and 1.4 m/s.\",\"PeriodicalId\":126960,\"journal\":{\"name\":\"2011 20th European Conference on Circuit Theory and Design (ECCTD)\",\"volume\":\"412 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 20th European Conference on Circuit Theory and Design (ECCTD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCTD.2011.6043374\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 20th European Conference on Circuit Theory and Design (ECCTD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCTD.2011.6043374","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Signal characterization of a pulsed-wire and heat flow system at a flow sensor
This article describes a pulsed thermal Time-of-Flight (TTOF) flow sensor system as two subsystems i.e., a pulsed-wire system and a heat flow system. The entire flow sensor is regarded system-theoretically as a linear time-invariant (LTI) system and is described by its transfer function or impulse response. The characterization of the thermo-fluid dynamic signals obtained by a pulsed-wire and by a heat flow is strived. Hence, the impulse response of both pulsed-wire and heat flow is analyzed according to the flow velocity. Experimental and theoretical results are compared in a flow velocity range in air between 0.1 m/s and 1.4 m/s.