在存在纵向和横向不对称的管道上确定高压OPL产生的感应电压

A. Cherepanov, A. Kryukov
{"title":"在存在纵向和横向不对称的管道上确定高压OPL产生的感应电压","authors":"A. Cherepanov, A. Kryukov","doi":"10.1109/UralCon49858.2020.9216260","DOIUrl":null,"url":null,"abstract":"The routes of steel pipelines can pass along highvoltage OPL. Hazardous voltages can be induced on OPL structural parts due to OPL electromagnetic influence, thus creating health risks for the personnel servicing the pipeline. The highest voltages are observed in unsymmetrical modes when currents flow in the earth. Therefore, the problem of quantitative assessment of the induced voltages levels in the presence of longitudinal and transversal unsymmetry is urgent. To solve this problem, methods of simulating non-symmetrical modes of electrical energy systems (EES) were used; the methods were developed at the Irkutsk State Transport University and are based on the EES elements multiphase representation. The simulation was implemented using the Fazonord software application. The technique has been proposed, which allows to determine the induced voltage generated by high-voltage power lines on the parallel surface pipeline in unsymmetrical modes. The technique can be used to develop actions aimed at the protection of personnel operating pipelines in areas located in zones of electromagnetic effects of high-voltage OPL. The technique can be generalized in the event of non-parallel length of exposure of the pipeline and OPL. This work was financially supported by the grant “Improving the quality of electric energy and electromagnetic safety in railway power supply systems equipped with Smart Grid devices by applying methods and means of mathematical modeling based on phase coordinates”.","PeriodicalId":230353,"journal":{"name":"2020 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determining the Induced Voltages, Generated By High-Voltage OPL, on a Pipeline in the Presence of Longitudinal and Transversal Unsymmetry\",\"authors\":\"A. Cherepanov, A. Kryukov\",\"doi\":\"10.1109/UralCon49858.2020.9216260\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The routes of steel pipelines can pass along highvoltage OPL. Hazardous voltages can be induced on OPL structural parts due to OPL electromagnetic influence, thus creating health risks for the personnel servicing the pipeline. The highest voltages are observed in unsymmetrical modes when currents flow in the earth. Therefore, the problem of quantitative assessment of the induced voltages levels in the presence of longitudinal and transversal unsymmetry is urgent. To solve this problem, methods of simulating non-symmetrical modes of electrical energy systems (EES) were used; the methods were developed at the Irkutsk State Transport University and are based on the EES elements multiphase representation. The simulation was implemented using the Fazonord software application. The technique has been proposed, which allows to determine the induced voltage generated by high-voltage power lines on the parallel surface pipeline in unsymmetrical modes. The technique can be used to develop actions aimed at the protection of personnel operating pipelines in areas located in zones of electromagnetic effects of high-voltage OPL. The technique can be generalized in the event of non-parallel length of exposure of the pipeline and OPL. This work was financially supported by the grant “Improving the quality of electric energy and electromagnetic safety in railway power supply systems equipped with Smart Grid devices by applying methods and means of mathematical modeling based on phase coordinates”.\",\"PeriodicalId\":230353,\"journal\":{\"name\":\"2020 International Ural Conference on Electrical Power Engineering (UralCon)\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 International Ural Conference on Electrical Power Engineering (UralCon)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UralCon49858.2020.9216260\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Ural Conference on Electrical Power Engineering (UralCon)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UralCon49858.2020.9216260","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

钢质管线的路线可以通过高压管线。由于OPL的电磁影响,OPL结构部件上可能产生危险电压,从而对管道维修人员造成健康风险。当电流在大地中流动时,在不对称模式下观察到最高电压。因此,在存在纵向和横向不对称的情况下,对感应电压水平进行定量评估的问题迫在眉睫。为了解决这一问题,采用了模拟电能系统非对称模式的方法;这些方法是在伊尔库茨克国立交通大学开发的,基于EES元素多相表示。仿真采用Fazonord软件实现。提出了一种测量高压线路在非对称模式下在并联表面管道上产生的感应电压的方法。该技术可用于制定旨在保护位于高压OPL电磁效应区域的管道操作人员的行动。该技术可以推广到管道和OPL暴露长度不平行的情况。本工作得到“应用基于相位坐标的数学建模方法和手段提高智能电网铁路供电系统电能质量和电磁安全”项目资助。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determining the Induced Voltages, Generated By High-Voltage OPL, on a Pipeline in the Presence of Longitudinal and Transversal Unsymmetry
The routes of steel pipelines can pass along highvoltage OPL. Hazardous voltages can be induced on OPL structural parts due to OPL electromagnetic influence, thus creating health risks for the personnel servicing the pipeline. The highest voltages are observed in unsymmetrical modes when currents flow in the earth. Therefore, the problem of quantitative assessment of the induced voltages levels in the presence of longitudinal and transversal unsymmetry is urgent. To solve this problem, methods of simulating non-symmetrical modes of electrical energy systems (EES) were used; the methods were developed at the Irkutsk State Transport University and are based on the EES elements multiphase representation. The simulation was implemented using the Fazonord software application. The technique has been proposed, which allows to determine the induced voltage generated by high-voltage power lines on the parallel surface pipeline in unsymmetrical modes. The technique can be used to develop actions aimed at the protection of personnel operating pipelines in areas located in zones of electromagnetic effects of high-voltage OPL. The technique can be generalized in the event of non-parallel length of exposure of the pipeline and OPL. This work was financially supported by the grant “Improving the quality of electric energy and electromagnetic safety in railway power supply systems equipped with Smart Grid devices by applying methods and means of mathematical modeling based on phase coordinates”.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of Statistical Information for Data Trend Forecasting Analysis of Power Oscillations Parameters in Autonomous Electrical Complexes Using the Method of Customization Charts Designing System for Cleaning the Surface of Solar Modules from Dust Pollution Analysis of Power Quality and Pumping Units Operation's Optimization Device for Data Communication along Power Lines
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1