基于等效阻抗的电力系统电压控制

A. Kechroud, J. Myrzik, W. Kling
{"title":"基于等效阻抗的电力系统电压控制","authors":"A. Kechroud, J. Myrzik, W. Kling","doi":"10.1109/PES.2009.5260224","DOIUrl":null,"url":null,"abstract":"Voltage control is traditionally achieved through reactive power control, mainly because of the inductive nature of the transmission grids. However, when considering distribution networks, reactive power may not be an effective mean for voltage control. This is because of the X/R ratio which determines the controllability of voltage through active and/or reactive power. Therefore, in this paper a voltage control scheme is proposed based on the estimation of the X/R ratio of the grid. The estimated X/R will then be used to determine the active and reactive power to be injected into the grid in order to keep the voltage between permissible limits.","PeriodicalId":258632,"journal":{"name":"2009 IEEE Power & Energy Society General Meeting","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"A power system equivalent impedance based voltage control\",\"authors\":\"A. Kechroud, J. Myrzik, W. Kling\",\"doi\":\"10.1109/PES.2009.5260224\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Voltage control is traditionally achieved through reactive power control, mainly because of the inductive nature of the transmission grids. However, when considering distribution networks, reactive power may not be an effective mean for voltage control. This is because of the X/R ratio which determines the controllability of voltage through active and/or reactive power. Therefore, in this paper a voltage control scheme is proposed based on the estimation of the X/R ratio of the grid. The estimated X/R will then be used to determine the active and reactive power to be injected into the grid in order to keep the voltage between permissible limits.\",\"PeriodicalId\":258632,\"journal\":{\"name\":\"2009 IEEE Power & Energy Society General Meeting\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE Power & Energy Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PES.2009.5260224\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE Power & Energy Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2009.5260224","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

电压控制传统上是通过无功功率控制来实现的,这主要是因为输电网的感应特性。然而,当考虑配电网时,无功功率可能不是电压控制的有效手段。这是因为X/R比率决定了电压的可控性,通过有功和/或无功功率。因此,本文提出了一种基于电网X/R比值估计的电压控制方案。然后,估计的X/R将用于确定注入电网的有功功率和无功功率,以便将电压保持在允许的范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A power system equivalent impedance based voltage control
Voltage control is traditionally achieved through reactive power control, mainly because of the inductive nature of the transmission grids. However, when considering distribution networks, reactive power may not be an effective mean for voltage control. This is because of the X/R ratio which determines the controllability of voltage through active and/or reactive power. Therefore, in this paper a voltage control scheme is proposed based on the estimation of the X/R ratio of the grid. The estimated X/R will then be used to determine the active and reactive power to be injected into the grid in order to keep the voltage between permissible limits.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Substation fault analysis requirements On field experience results related to high-impedance faults in power distribution system Reactive power compensation using Z-source based photovoltaic system How can flicker level be determined before a customer is connected to the electric grid Transmission expansion and pricing in Colombia: An appraisal of current practices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1