Abdelrahman Ayad, Mohsen Khalaf, E. El-Saadany
{"title":"考虑系统非线性的自动生成控制系统中假数据注入攻击检测","authors":"Abdelrahman Ayad, Mohsen Khalaf, E. El-Saadany","doi":"10.1109/EPEC.2018.8598328","DOIUrl":null,"url":null,"abstract":"Maintaining the power system frequency around its nominal value is a very critical issue for the system stability. This operation is performed by the Automatic Generation Control (AGC) system. A cyber attack on the AGC system may affect the whole stability and economic operation of the power system. This paper proposes a method using Recurrent Neural Networks to detect False Data Injection (FDI) attacks in AGC systems. The novelty of this work over other approaches is that the nonlinearities of the AGC system are considered, which make it difficult to use the conventional approaches to detect FDI in case of considering the nonlinearities. The AGC of a two-area power system is used and the results show that the proposed approach succeeded to detect FDI in AGC system with an accuracy of 94%.","PeriodicalId":265297,"journal":{"name":"2018 IEEE Electrical Power and Energy Conference (EPEC)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Detection of False Data Injection Attacks in Automatic Generation Control Systems Considering System Nonlinearities\",\"authors\":\"Abdelrahman Ayad, Mohsen Khalaf, E. El-Saadany\",\"doi\":\"10.1109/EPEC.2018.8598328\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Maintaining the power system frequency around its nominal value is a very critical issue for the system stability. This operation is performed by the Automatic Generation Control (AGC) system. A cyber attack on the AGC system may affect the whole stability and economic operation of the power system. This paper proposes a method using Recurrent Neural Networks to detect False Data Injection (FDI) attacks in AGC systems. The novelty of this work over other approaches is that the nonlinearities of the AGC system are considered, which make it difficult to use the conventional approaches to detect FDI in case of considering the nonlinearities. The AGC of a two-area power system is used and the results show that the proposed approach succeeded to detect FDI in AGC system with an accuracy of 94%.\",\"PeriodicalId\":265297,\"journal\":{\"name\":\"2018 IEEE Electrical Power and Energy Conference (EPEC)\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Electrical Power and Energy Conference (EPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPEC.2018.8598328\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Electrical Power and Energy Conference (EPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEC.2018.8598328","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

维持电力系统频率在其标称值附近是一个非常关键的问题,它关系到系统的稳定性。该操作由AGC (Automatic Generation Control)系统执行。对AGC系统的网络攻击可能会影响整个电力系统的稳定性和经济运行。提出了一种利用递归神经网络检测AGC系统中虚假数据注入(FDI)攻击的方法。与其他方法相比,这项工作的新颖之处在于考虑了AGC系统的非线性,这使得在考虑非线性的情况下难以使用传统方法来检测FDI。实验结果表明,该方法能有效地检测出两区电力系统中的FDI,准确率达94%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Detection of False Data Injection Attacks in Automatic Generation Control Systems Considering System Nonlinearities
Maintaining the power system frequency around its nominal value is a very critical issue for the system stability. This operation is performed by the Automatic Generation Control (AGC) system. A cyber attack on the AGC system may affect the whole stability and economic operation of the power system. This paper proposes a method using Recurrent Neural Networks to detect False Data Injection (FDI) attacks in AGC systems. The novelty of this work over other approaches is that the nonlinearities of the AGC system are considered, which make it difficult to use the conventional approaches to detect FDI in case of considering the nonlinearities. The AGC of a two-area power system is used and the results show that the proposed approach succeeded to detect FDI in AGC system with an accuracy of 94%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Power Mismatch Elimination Strategy for an MMC-based PV System in Unbalanced Grids Implementation and Testing of a Hybrid Protection Scheme for Active Distribution Network Evaluation of Parametric Statistical Models for Wind Speed Probability Density Estimation Modeling of Ferroresonance Phenomena in MV Networks Emulating Subsynchronous Resonance using Hardware and Software Implementation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1