{"title":"时间范围(TIR)在糖尿病临床实践中连续血糖监测(CGM)的重要性","authors":"H. Bando","doi":"10.33805/2690-2613.119","DOIUrl":null,"url":null,"abstract":"As to the development of treatment for diabetes, Continuous Glucose Monitoring (CGM) has been recently prevalent rapidly. By the analysis of real-time CGM, Ambulatory Glucose Profile (AGP) has been used. It includes time in range (TIR, 70-180 mg/dL), time above range (TAR, >181mg/dL), time below range (TBR, <69 mg/dL), Glycemic Variability (GV), Glucose Management Indicator (GMI), Glycemic variability, Coefficient Of Variation (CV%) and so on. TIR value indicating approximately 70% seems to correlate closely with the HbA1c level of 6.77.0%. Marked discordance of HbA1c values has been found between laboratory HbA1c and estimated HbA1c (eA1c) using GMI from CGM.","PeriodicalId":315411,"journal":{"name":"Edelweiss Journal of Biomedical Research and Review","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Importance of Time in Range (TIR) for Continuous Glucose Monitoring (CGM) in the Clinical Practice for Diabetes\",\"authors\":\"H. Bando\",\"doi\":\"10.33805/2690-2613.119\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As to the development of treatment for diabetes, Continuous Glucose Monitoring (CGM) has been recently prevalent rapidly. By the analysis of real-time CGM, Ambulatory Glucose Profile (AGP) has been used. It includes time in range (TIR, 70-180 mg/dL), time above range (TAR, >181mg/dL), time below range (TBR, <69 mg/dL), Glycemic Variability (GV), Glucose Management Indicator (GMI), Glycemic variability, Coefficient Of Variation (CV%) and so on. TIR value indicating approximately 70% seems to correlate closely with the HbA1c level of 6.77.0%. Marked discordance of HbA1c values has been found between laboratory HbA1c and estimated HbA1c (eA1c) using GMI from CGM.\",\"PeriodicalId\":315411,\"journal\":{\"name\":\"Edelweiss Journal of Biomedical Research and Review\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Edelweiss Journal of Biomedical Research and Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33805/2690-2613.119\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Edelweiss Journal of Biomedical Research and Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33805/2690-2613.119","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Importance of Time in Range (TIR) for Continuous Glucose Monitoring (CGM) in the Clinical Practice for Diabetes
As to the development of treatment for diabetes, Continuous Glucose Monitoring (CGM) has been recently prevalent rapidly. By the analysis of real-time CGM, Ambulatory Glucose Profile (AGP) has been used. It includes time in range (TIR, 70-180 mg/dL), time above range (TAR, >181mg/dL), time below range (TBR, <69 mg/dL), Glycemic Variability (GV), Glucose Management Indicator (GMI), Glycemic variability, Coefficient Of Variation (CV%) and so on. TIR value indicating approximately 70% seems to correlate closely with the HbA1c level of 6.77.0%. Marked discordance of HbA1c values has been found between laboratory HbA1c and estimated HbA1c (eA1c) using GMI from CGM.