自然框架三相并联有源电力滤波器的滑模控制

Ramón Guzmán, L. G. D. Vicuña, J. Morales, M. Castilla, J. Miret, Javier Torres-Martínez
{"title":"自然框架三相并联有源电力滤波器的滑模控制","authors":"Ramón Guzmán, L. G. D. Vicuña, J. Morales, M. Castilla, J. Miret, Javier Torres-Martínez","doi":"10.1109/IECON.2015.7392265","DOIUrl":null,"url":null,"abstract":"This paper presents an improved variable hysteresis-band current-control in natural frame for a three-phase shunt active power filter. The proposed control algorithm is based on three decoupled sliding-mode controllers combined with three independent Kalman filters. The use of Kalman filters instead of a non-adaptive state observer improves the quality of the estimated signals in presence of noise, increasing the immunity of the control loop in noisy environments and also reducing the THD of the current delivered to the grid. The overall control proposal has been fully integrated into a digital signal processor. Selected experimental results are introduced to validate the theoretical contributions of this paper.","PeriodicalId":190550,"journal":{"name":"IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Sliding-mode control for a three-phase shunt active power filter in natural frame\",\"authors\":\"Ramón Guzmán, L. G. D. Vicuña, J. Morales, M. Castilla, J. Miret, Javier Torres-Martínez\",\"doi\":\"10.1109/IECON.2015.7392265\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an improved variable hysteresis-band current-control in natural frame for a three-phase shunt active power filter. The proposed control algorithm is based on three decoupled sliding-mode controllers combined with three independent Kalman filters. The use of Kalman filters instead of a non-adaptive state observer improves the quality of the estimated signals in presence of noise, increasing the immunity of the control loop in noisy environments and also reducing the THD of the current delivered to the grid. The overall control proposal has been fully integrated into a digital signal processor. Selected experimental results are introduced to validate the theoretical contributions of this paper.\",\"PeriodicalId\":190550,\"journal\":{\"name\":\"IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.2015.7392265\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.2015.7392265","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文提出了一种改进的三相并联有源电力滤波器自然框架可变迟滞带电流控制方法。该控制算法基于三个解耦滑模控制器和三个独立的卡尔曼滤波器。使用卡尔曼滤波器代替非自适应状态观测器提高了存在噪声时估计信号的质量,增加了控制回路在噪声环境中的抗扰度,也降低了输送到电网的电流的THD。整个控制方案已经完全集成到一个数字信号处理器中。通过实验结果验证了本文的理论贡献。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Sliding-mode control for a three-phase shunt active power filter in natural frame
This paper presents an improved variable hysteresis-band current-control in natural frame for a three-phase shunt active power filter. The proposed control algorithm is based on three decoupled sliding-mode controllers combined with three independent Kalman filters. The use of Kalman filters instead of a non-adaptive state observer improves the quality of the estimated signals in presence of noise, increasing the immunity of the control loop in noisy environments and also reducing the THD of the current delivered to the grid. The overall control proposal has been fully integrated into a digital signal processor. Selected experimental results are introduced to validate the theoretical contributions of this paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A new combined bidirectional boost converter and battery charger for electric vehicles Mixed strategist dynamics application to electrical vehicle distributed load scheduling DC fault isolation study of bidirectional dual active bridge DC/DC converter for DC transmission grid application A combined switched reluctance motor drive and battery charger for electric vehicles Experimental validation of a proposed single-phase five-level active rectifier operating with model predictive current control
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1