{"title":"可穿戴生物医学系统CMOS限制放大器的设计考虑","authors":"J. Ramos, J. L. Ausín, J. F. Duque-Carrillo, G. Torelli","doi":"10.1109/ECCTD.2011.6043344","DOIUrl":null,"url":null,"abstract":"This paper presents design considerations on CMOS limiting amplifiers to be used as basic building blocks for power-efficient logarithmic amplifiers. The impact of mismatches and device-level properties on sensitivity and gain-bandwidth product is discussed. To this end, a comparison of several types of low-voltage gain cell topologies is presented. Based on statistical (Monte Carlo) results, a high-sensitivity eight-stage limiting amplifier tolerant of process and mismatch variations was designed in 0.35-µm CMOS technology to operate over a dc-to-20-MHz bandwidth. The proposed limiting amplifier draws 280 µA from a 2-V supply and achieves a voltage gain of 75 dB.","PeriodicalId":126960,"journal":{"name":"2011 20th European Conference on Circuit Theory and Design (ECCTD)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Design considerations on CMOS limiting amplifiers for wearable biomedical systems\",\"authors\":\"J. Ramos, J. L. Ausín, J. F. Duque-Carrillo, G. Torelli\",\"doi\":\"10.1109/ECCTD.2011.6043344\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents design considerations on CMOS limiting amplifiers to be used as basic building blocks for power-efficient logarithmic amplifiers. The impact of mismatches and device-level properties on sensitivity and gain-bandwidth product is discussed. To this end, a comparison of several types of low-voltage gain cell topologies is presented. Based on statistical (Monte Carlo) results, a high-sensitivity eight-stage limiting amplifier tolerant of process and mismatch variations was designed in 0.35-µm CMOS technology to operate over a dc-to-20-MHz bandwidth. The proposed limiting amplifier draws 280 µA from a 2-V supply and achieves a voltage gain of 75 dB.\",\"PeriodicalId\":126960,\"journal\":{\"name\":\"2011 20th European Conference on Circuit Theory and Design (ECCTD)\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 20th European Conference on Circuit Theory and Design (ECCTD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCTD.2011.6043344\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 20th European Conference on Circuit Theory and Design (ECCTD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCTD.2011.6043344","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文介绍了CMOS限制放大器的设计考虑,以作为节能对数放大器的基本构建模块。讨论了不匹配和器件级特性对灵敏度和增益-带宽积的影响。为此,对几种类型的低压增益单元拓扑结构进行了比较。基于统计(蒙特卡罗)结果,采用0.35µm CMOS技术设计了一个高灵敏度的8级限幅放大器,可容忍工艺和失配变化,工作带宽为dc- 20mhz。所提出的限制放大器从2 v电源中吸取280µA,并实现75 dB的电压增益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design considerations on CMOS limiting amplifiers for wearable biomedical systems
This paper presents design considerations on CMOS limiting amplifiers to be used as basic building blocks for power-efficient logarithmic amplifiers. The impact of mismatches and device-level properties on sensitivity and gain-bandwidth product is discussed. To this end, a comparison of several types of low-voltage gain cell topologies is presented. Based on statistical (Monte Carlo) results, a high-sensitivity eight-stage limiting amplifier tolerant of process and mismatch variations was designed in 0.35-µm CMOS technology to operate over a dc-to-20-MHz bandwidth. The proposed limiting amplifier draws 280 µA from a 2-V supply and achieves a voltage gain of 75 dB.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Decade bandwidth single and cascaded travelling wave medium power amplifiers using sige hbts Hilbert transform by divide-and-conquer piecewise linear approximation Analysis and design of an array of two differential oscillators coupled through a resistive network Impact of NMOS/PMOS imbalance in Ultra-Low Voltage CMOS standard cells Utilization of distortion contribution analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1