{"title":"利用模型物理参数解析表达式预测光伏太阳能组件峰值功率和效率的温度和入射辐照度实时监测","authors":"M. Zaimi, H. E. Achouby, A. Ibral, E. Assaid, M. Maliki, R. Saadani","doi":"10.1109/IRSEC.2018.8702973","DOIUrl":null,"url":null,"abstract":"In this paper, we proceed to a daily monitoring of module temperature T and incident solar irradiance G received on south faced tilted fixed photovoltaic solar module modelled by single diode equivalent electronic circuit. We assume that module series resistance Rs and shunt conductance Gp are constant and equal to values corresponding to standard test conditions (STC). We derive new analytical expressions describing variations of photocurrent Iph, ideality factor η and saturation current Is as functions of temperature T and irradiance G, using temperature coefficients available and irradiance coefficients extracted from manufacturer’s datasheet. We determine analytically and numerically variations of photocurrent, ideality factor and saturation current throughout a day. We deduce temporal evolving of maximum power point current Impp, maximum power point voltage Vmpp and module efficiency of Sunmodule plus SW255 polycrystalline silicon based photovoltaic solar module and compare with maximum power point and module efficiency experimental data. We raise a very good agreement between predicted values and experimental measurements.","PeriodicalId":186042,"journal":{"name":"2018 6th International Renewable and Sustainable Energy Conference (IRSEC)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Temporal Monitoring of Temperature and Incident Irradiance for Predicting Photovoltaic Solar Module Peak Power and Efficiency using Analytical Expressions of Model Physical Parameters\",\"authors\":\"M. Zaimi, H. E. Achouby, A. Ibral, E. Assaid, M. Maliki, R. Saadani\",\"doi\":\"10.1109/IRSEC.2018.8702973\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, we proceed to a daily monitoring of module temperature T and incident solar irradiance G received on south faced tilted fixed photovoltaic solar module modelled by single diode equivalent electronic circuit. We assume that module series resistance Rs and shunt conductance Gp are constant and equal to values corresponding to standard test conditions (STC). We derive new analytical expressions describing variations of photocurrent Iph, ideality factor η and saturation current Is as functions of temperature T and irradiance G, using temperature coefficients available and irradiance coefficients extracted from manufacturer’s datasheet. We determine analytically and numerically variations of photocurrent, ideality factor and saturation current throughout a day. We deduce temporal evolving of maximum power point current Impp, maximum power point voltage Vmpp and module efficiency of Sunmodule plus SW255 polycrystalline silicon based photovoltaic solar module and compare with maximum power point and module efficiency experimental data. We raise a very good agreement between predicted values and experimental measurements.\",\"PeriodicalId\":186042,\"journal\":{\"name\":\"2018 6th International Renewable and Sustainable Energy Conference (IRSEC)\",\"volume\":\"57 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 6th International Renewable and Sustainable Energy Conference (IRSEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IRSEC.2018.8702973\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 6th International Renewable and Sustainable Energy Conference (IRSEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IRSEC.2018.8702973","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文采用单二极管等效电子电路,对组件温度T和接收到的南向倾斜固定光伏太阳能组件的入射太阳辐照度G进行了日常监测。我们假设模块串联电阻Rs和分流电导Gp是恒定的,且等于标准测试条件(STC)对应的值。我们利用现有的温度系数和从制造商数据表中提取的辐照系数,推导出描述光电流Iph、理想因子η和饱和电流Is随温度T和辐照度G变化的新的解析表达式。我们用分析和数值方法确定一天中光电流、理想系数和饱和电流的变化。我们推导了Sunmodule + SW255多晶硅基光伏太阳能组件的最大功率点电流Impp、最大功率点电压Vmpp和组件效率的时间演化,并与最大功率点和组件效率实验数据进行了比较。我们提出了预测值和实验测量值非常吻合的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Temporal Monitoring of Temperature and Incident Irradiance for Predicting Photovoltaic Solar Module Peak Power and Efficiency using Analytical Expressions of Model Physical Parameters
In this paper, we proceed to a daily monitoring of module temperature T and incident solar irradiance G received on south faced tilted fixed photovoltaic solar module modelled by single diode equivalent electronic circuit. We assume that module series resistance Rs and shunt conductance Gp are constant and equal to values corresponding to standard test conditions (STC). We derive new analytical expressions describing variations of photocurrent Iph, ideality factor η and saturation current Is as functions of temperature T and irradiance G, using temperature coefficients available and irradiance coefficients extracted from manufacturer’s datasheet. We determine analytically and numerically variations of photocurrent, ideality factor and saturation current throughout a day. We deduce temporal evolving of maximum power point current Impp, maximum power point voltage Vmpp and module efficiency of Sunmodule plus SW255 polycrystalline silicon based photovoltaic solar module and compare with maximum power point and module efficiency experimental data. We raise a very good agreement between predicted values and experimental measurements.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparative Structural and Modal Analysis of a Wind Turbine Planetary Gear Based on Material Cut Criteria using FEM Formulation And Thermal Potentials Of An Eco-Material For Civil Engeneering Structural Analysis of Wind Turbine Epicyclical Gear System by FEM Electrification of Rural and Arid Areas by Solar Energy Applications Control Strategies of PMSG Wind Energy Conversion System Based on Five Level NPC Converter
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1