{"title":"根据CISPR 32使用RMS-Average探测器对多媒体设备进行辐射测量","authors":"J. Medler","doi":"10.1109/APEMC.2016.7522989","DOIUrl":null,"url":null,"abstract":"Purpose of weighting along with the defined weighting function for the new RMS-Average detector is introduced. Extensive comparison measurements on multimedia equipment in the scope of CISPR 32 were performed using the required Quasi-Peak and Average detectors and the RMS-Average detector for both conducted and radiated emission measurements to confirm the weighting function and for the definition of emission limits for the RMS-Average detector.","PeriodicalId":358257,"journal":{"name":"2016 Asia-Pacific International Symposium on Electromagnetic Compatibility (APEMC)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of RMS-Average detector for emission measurements on multimedia equipment in accordance with CISPR 32\",\"authors\":\"J. Medler\",\"doi\":\"10.1109/APEMC.2016.7522989\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose of weighting along with the defined weighting function for the new RMS-Average detector is introduced. Extensive comparison measurements on multimedia equipment in the scope of CISPR 32 were performed using the required Quasi-Peak and Average detectors and the RMS-Average detector for both conducted and radiated emission measurements to confirm the weighting function and for the definition of emission limits for the RMS-Average detector.\",\"PeriodicalId\":358257,\"journal\":{\"name\":\"2016 Asia-Pacific International Symposium on Electromagnetic Compatibility (APEMC)\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 Asia-Pacific International Symposium on Electromagnetic Compatibility (APEMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEMC.2016.7522989\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Asia-Pacific International Symposium on Electromagnetic Compatibility (APEMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEMC.2016.7522989","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Use of RMS-Average detector for emission measurements on multimedia equipment in accordance with CISPR 32
Purpose of weighting along with the defined weighting function for the new RMS-Average detector is introduced. Extensive comparison measurements on multimedia equipment in the scope of CISPR 32 were performed using the required Quasi-Peak and Average detectors and the RMS-Average detector for both conducted and radiated emission measurements to confirm the weighting function and for the definition of emission limits for the RMS-Average detector.