浊度控制用水采用比浊度计最佳分布净化法

B. R. Jabbarli
{"title":"浊度控制用水采用比浊度计最佳分布净化法","authors":"B. R. Jabbarli","doi":"10.14489/td.2022.11.pp.052-056","DOIUrl":null,"url":null,"abstract":"A method of water turbidity control using ratio turbidimeters is proposed for the implementation of optimal distributed water purification. The problem of minimizing the total turbidity value in NTU units of readings generated at the outputs of ratio turbidimeters included in each subchannel of the water flow distribution network is substantiated and solved. In the subchannels, the water is purified using coagulation-flocculation technology. The optimal ratio of the turbidimeter signals of the ratio is obtained, at which the sum of the NTU readings of the subchannels reaches a minimum.","PeriodicalId":432853,"journal":{"name":"Kontrol'. Diagnostika","volume":"74 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"TURBIDITY CONTROL OF WATER USING RATIO TURBIDIMETERS THE METHOD OF OPTIMAL DISTRIBUTED PURIFICATION\",\"authors\":\"B. R. Jabbarli\",\"doi\":\"10.14489/td.2022.11.pp.052-056\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method of water turbidity control using ratio turbidimeters is proposed for the implementation of optimal distributed water purification. The problem of minimizing the total turbidity value in NTU units of readings generated at the outputs of ratio turbidimeters included in each subchannel of the water flow distribution network is substantiated and solved. In the subchannels, the water is purified using coagulation-flocculation technology. The optimal ratio of the turbidimeter signals of the ratio is obtained, at which the sum of the NTU readings of the subchannels reaches a minimum.\",\"PeriodicalId\":432853,\"journal\":{\"name\":\"Kontrol'. Diagnostika\",\"volume\":\"74 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kontrol'. Diagnostika\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14489/td.2022.11.pp.052-056\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kontrol'. Diagnostika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14489/td.2022.11.pp.052-056","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

提出了一种利用比浊度仪控制水浊度的方法,以实现最优的分布式水净化。验证并解决了水流配网各子通道的比例浊度计输出的读数以NTU单位为单位的总浊度值最小的问题。在子通道中,采用混凝-絮凝技术对水进行净化。得到了比浊度计信号的最佳比,在此比浊度计各子通道的NTU读数之和达到最小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
TURBIDITY CONTROL OF WATER USING RATIO TURBIDIMETERS THE METHOD OF OPTIMAL DISTRIBUTED PURIFICATION
A method of water turbidity control using ratio turbidimeters is proposed for the implementation of optimal distributed water purification. The problem of minimizing the total turbidity value in NTU units of readings generated at the outputs of ratio turbidimeters included in each subchannel of the water flow distribution network is substantiated and solved. In the subchannels, the water is purified using coagulation-flocculation technology. The optimal ratio of the turbidimeter signals of the ratio is obtained, at which the sum of the NTU readings of the subchannels reaches a minimum.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
DIAGNOSTICS OF INTERELECTRODE GAP’S CONDITION USING VIBROACOUSTIC EMISSION APPLICATION OF ACOUSTIC EMISSION METHOD FOR DETECTING DIFFUSION INTERLAYERS IN DIFFERENT WELDED JOINTS CALIBRATION OF THE PIEZOELECTRIC DYNAMOMETER KISTLER USING A MEASURING DEVICE BASED ON A SAMPLE COMPRESSION DYNAMOMETER TOPOLOGY OF MANUFACTURING A SORPTION-CAPACITIVE HUMIDITY SENSOR BASED ON THIN FILMS OBTAINED BY MICROARC OXIDATION AND MAGNETRON SPUTTERING INVESTIGATION OF THE TEMPERATURE ERROR OF COORDINATE MEASURING MACHINES
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1