{"title":"275 kV气体绝缘变电站建模及快速暂态过电压分析与缓解","authors":"T. N. Shanavas, Krishna K Bharath, Anglight Sunny, P. M. Anju, Aman Rajeev","doi":"10.1109/ComPE53109.2021.9752051","DOIUrl":null,"url":null,"abstract":"Power demand in the modern era is more than ever before but there is the limitation of space availability in densely populated areas. Owing to the less space requirement Gas Insulated Substations (GIS) are expected to dominate the power transmission utility. A gas-insulated substation uses a superior dielectric gas, SF6, at moderate pressure for phase-to-phase and phase-to-ground insulation. The switching events in GIS result in the generation of Very Fast Transient Overvoltages (VFTO). By using PSCAD software, VFTO has been simulated in a 275 kV gas-insulated substation. The GIS components are represented using equivalent circuits. VFTO generated by simulating the switching events is analyzed using STFT and CWT analysis. Mitigation of VFTO using ferrite rings is evaluated by implementing the equivalent model in the substation model.","PeriodicalId":211704,"journal":{"name":"2021 International Conference on Computational Performance Evaluation (ComPE)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Modeling of 275 kV Gas Insulated Substation and Analysis and Mitigation of Very Fast Transient Overvoltages\",\"authors\":\"T. N. Shanavas, Krishna K Bharath, Anglight Sunny, P. M. Anju, Aman Rajeev\",\"doi\":\"10.1109/ComPE53109.2021.9752051\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power demand in the modern era is more than ever before but there is the limitation of space availability in densely populated areas. Owing to the less space requirement Gas Insulated Substations (GIS) are expected to dominate the power transmission utility. A gas-insulated substation uses a superior dielectric gas, SF6, at moderate pressure for phase-to-phase and phase-to-ground insulation. The switching events in GIS result in the generation of Very Fast Transient Overvoltages (VFTO). By using PSCAD software, VFTO has been simulated in a 275 kV gas-insulated substation. The GIS components are represented using equivalent circuits. VFTO generated by simulating the switching events is analyzed using STFT and CWT analysis. Mitigation of VFTO using ferrite rings is evaluated by implementing the equivalent model in the substation model.\",\"PeriodicalId\":211704,\"journal\":{\"name\":\"2021 International Conference on Computational Performance Evaluation (ComPE)\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Computational Performance Evaluation (ComPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ComPE53109.2021.9752051\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Computational Performance Evaluation (ComPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ComPE53109.2021.9752051","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

现代社会的电力需求比以往任何时候都要多,但在人口稠密的地区,可用空间有限。由于对空间的要求较少,气体绝缘变电站有望在输电事业中占据主导地位。气体绝缘变电站采用优良的介质气体SF6,在中等压力下进行相对相和相对地绝缘。GIS中的开关事件会导致快速瞬态过电压的产生。利用PSCAD软件对275 kV气体绝缘变电站的变频振荡器进行了仿真。GIS组件用等效电路表示。利用STFT和CWT分析方法对模拟开关事件产生的VFTO进行了分析。通过在变电站模型中引入等效模型,评估了铁氧体环对VFTO的抑制作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Modeling of 275 kV Gas Insulated Substation and Analysis and Mitigation of Very Fast Transient Overvoltages
Power demand in the modern era is more than ever before but there is the limitation of space availability in densely populated areas. Owing to the less space requirement Gas Insulated Substations (GIS) are expected to dominate the power transmission utility. A gas-insulated substation uses a superior dielectric gas, SF6, at moderate pressure for phase-to-phase and phase-to-ground insulation. The switching events in GIS result in the generation of Very Fast Transient Overvoltages (VFTO). By using PSCAD software, VFTO has been simulated in a 275 kV gas-insulated substation. The GIS components are represented using equivalent circuits. VFTO generated by simulating the switching events is analyzed using STFT and CWT analysis. Mitigation of VFTO using ferrite rings is evaluated by implementing the equivalent model in the substation model.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
iSIMP with Integrity Validation using MD5 Hash A Fault Detection Scheme for IoT-enabled WSNs YOLOv3 based Real Time Social Distance Violation Detection in Public Places Finite Element Analysis of Femur Bone under Different Loading Conditions An Efficient and Anonymous Authentication Key Agreement Protocol for Smart Transportation System
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1