芯片上的基础测序使用两阶段的反应控制方案:3.6倍的速度和1/100减少数据量基于isfet的DNA测序仪

Y. Yanagawa, N. Itabashi, S. Migitaka, Takahide Yokoi, Makiko Yoshida, T. Kawahara
{"title":"芯片上的基础测序使用两阶段的反应控制方案:3.6倍的速度和1/100减少数据量基于isfet的DNA测序仪","authors":"Y. Yanagawa, N. Itabashi, S. Migitaka, Takahide Yokoi, Makiko Yoshida, T. Kawahara","doi":"10.1109/BioCAS.2013.6679668","DOIUrl":null,"url":null,"abstract":"A novel two-stage reaction-control scheme with a background-cancelling circuit - for reducing data volume and analysis time of an ion-sensitive-FET (ISFET) - based DNA sequencer-is proposed. The scheme successfully reduces the background noise and renders time-consuming background analysis unnecessary. It also reduces sample-to-data time by 72% (3.6 times faster) and data volume by two orders of magnitude.","PeriodicalId":344317,"journal":{"name":"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"On-chip base sequencing using a two-stage reaction-control scheme: 3.6-times-faster and 1/100-reduced-data-volume ISFET-based DNA sequencer\",\"authors\":\"Y. Yanagawa, N. Itabashi, S. Migitaka, Takahide Yokoi, Makiko Yoshida, T. Kawahara\",\"doi\":\"10.1109/BioCAS.2013.6679668\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel two-stage reaction-control scheme with a background-cancelling circuit - for reducing data volume and analysis time of an ion-sensitive-FET (ISFET) - based DNA sequencer-is proposed. The scheme successfully reduces the background noise and renders time-consuming background analysis unnecessary. It also reduces sample-to-data time by 72% (3.6 times faster) and data volume by two orders of magnitude.\",\"PeriodicalId\":344317,\"journal\":{\"name\":\"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BioCAS.2013.6679668\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BioCAS.2013.6679668","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

为了减少离子敏感场效应管(ISFET) DNA测序仪的数据量和分析时间,提出了一种具有背景抵消电路的新型两级反应控制方案。该方案成功地降低了背景噪声,避免了耗时的背景分析。它还将样本到数据的时间缩短了72%(快了3.6倍),数据量减少了两个数量级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
On-chip base sequencing using a two-stage reaction-control scheme: 3.6-times-faster and 1/100-reduced-data-volume ISFET-based DNA sequencer
A novel two-stage reaction-control scheme with a background-cancelling circuit - for reducing data volume and analysis time of an ion-sensitive-FET (ISFET) - based DNA sequencer-is proposed. The scheme successfully reduces the background noise and renders time-consuming background analysis unnecessary. It also reduces sample-to-data time by 72% (3.6 times faster) and data volume by two orders of magnitude.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Multi-electrode amperometric biosensor for neurotransmitters detection A portable hardware implementation for temporal laser speckle imaging Automatic detection of sleep spindles using Teager energy and spectral edge frequency A 430nW 64nV/vHz current-reuse telescopic amplifier for neural recording applications Output stage of a current-steering multipolar and multisite deep brain stimulator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1