{"title":"静气介质中细长圆柱层流自然对流换热实验研究","authors":"A. Riaz, Ajmal Shah, A. Basit, M. Iqbal","doi":"10.1109/IBCAST.2019.8667230","DOIUrl":null,"url":null,"abstract":"In this paper, variation of local heat transfer coefficient from the surface of cylindrical heat source both in vertical as well as horizontal configuration has been determined through experimentation. Fourteen experiments were performed in an air quiescent medium in the laminar range to completely expedite the problem. Each experiment was repeated thrice to calculate precision of the data under steady state condition. This study includes the designing and manufacturing of heat sources, calibration of sensors, installation of thermocouples to measure surface temperature and obtaining of experimental results in the form of local dimensionless numbers. For experimentation, aluminum cylindrical heat source having 5.1 cm diameter and 31 cm lengths was employed. During experimentation, convective heat flux was varied from 9.39 w⁄m−2 to 638.99 w ⁄m−2 and maximum recorded temperature difference was 87.24 K for vertical heat source configuration and 116.49 K for horizontal configuration. Study shows that for vertical heat source configuration, local Nusselt number decreases from bottom to certain height and then increases; this is due to end losses. While in horizontal configuration of heat source, local Nusselt number is found maximum at the bottom and minimum at the top of the heat source. At the end, results were compared with the published data and were found satisfactory.","PeriodicalId":335329,"journal":{"name":"2019 16th International Bhurban Conference on Applied Sciences and Technology (IBCAST)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Experimental Study of Laminar Natural Convection Heat Transfer from Slender Circular Cylinder in Air Quiescent Medium\",\"authors\":\"A. Riaz, Ajmal Shah, A. Basit, M. Iqbal\",\"doi\":\"10.1109/IBCAST.2019.8667230\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, variation of local heat transfer coefficient from the surface of cylindrical heat source both in vertical as well as horizontal configuration has been determined through experimentation. Fourteen experiments were performed in an air quiescent medium in the laminar range to completely expedite the problem. Each experiment was repeated thrice to calculate precision of the data under steady state condition. This study includes the designing and manufacturing of heat sources, calibration of sensors, installation of thermocouples to measure surface temperature and obtaining of experimental results in the form of local dimensionless numbers. For experimentation, aluminum cylindrical heat source having 5.1 cm diameter and 31 cm lengths was employed. During experimentation, convective heat flux was varied from 9.39 w⁄m−2 to 638.99 w ⁄m−2 and maximum recorded temperature difference was 87.24 K for vertical heat source configuration and 116.49 K for horizontal configuration. Study shows that for vertical heat source configuration, local Nusselt number decreases from bottom to certain height and then increases; this is due to end losses. While in horizontal configuration of heat source, local Nusselt number is found maximum at the bottom and minimum at the top of the heat source. At the end, results were compared with the published data and were found satisfactory.\",\"PeriodicalId\":335329,\"journal\":{\"name\":\"2019 16th International Bhurban Conference on Applied Sciences and Technology (IBCAST)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 16th International Bhurban Conference on Applied Sciences and Technology (IBCAST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IBCAST.2019.8667230\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 16th International Bhurban Conference on Applied Sciences and Technology (IBCAST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IBCAST.2019.8667230","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文通过实验确定了圆柱热源表面在垂直和水平两种构型下的局部换热系数的变化规律。在层流范围内的空气静态介质中进行了14次实验,以完全简化问题。每个实验重复三次,计算稳态条件下数据的精度。本研究包括热源的设计与制造、传感器的校准、热电偶的安装以测量表面温度以及以局部无量纲数形式获得实验结果。实验采用直径5.1 cm、长31 cm的铝圆柱热源。实验过程中,对流热流密度在9.39 ~ 638.99 w / m−2之间变化,垂直热源配置的最大温差为87.24 K,水平热源配置的最大温差为116.49 K。研究表明,对于垂直热源配置,局部努塞尔数从底部到一定高度先减小后增大;这是由于期末损失。水平热源配置时,局部努塞尔数在热源底部最大,在热源顶部最小。最后,将结果与已发表的数据进行了比较,结果令人满意。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Experimental Study of Laminar Natural Convection Heat Transfer from Slender Circular Cylinder in Air Quiescent Medium
In this paper, variation of local heat transfer coefficient from the surface of cylindrical heat source both in vertical as well as horizontal configuration has been determined through experimentation. Fourteen experiments were performed in an air quiescent medium in the laminar range to completely expedite the problem. Each experiment was repeated thrice to calculate precision of the data under steady state condition. This study includes the designing and manufacturing of heat sources, calibration of sensors, installation of thermocouples to measure surface temperature and obtaining of experimental results in the form of local dimensionless numbers. For experimentation, aluminum cylindrical heat source having 5.1 cm diameter and 31 cm lengths was employed. During experimentation, convective heat flux was varied from 9.39 w⁄m−2 to 638.99 w ⁄m−2 and maximum recorded temperature difference was 87.24 K for vertical heat source configuration and 116.49 K for horizontal configuration. Study shows that for vertical heat source configuration, local Nusselt number decreases from bottom to certain height and then increases; this is due to end losses. While in horizontal configuration of heat source, local Nusselt number is found maximum at the bottom and minimum at the top of the heat source. At the end, results were compared with the published data and were found satisfactory.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparative Survey of Techniques and Technologies Used in Transmit Path of Transmit Receive Module of AESA Radar Testing-based Model Learning Approach for Legacy Components Pic Microcontroller Based Power Factor Correction for both Leading and Lagging Loads using Compensation Method Speed Tracking of Spark Ignition Engines using Higher Order Sliding Mode Control Survey of Authentication Schemes for Health Monitoring: A Subset of Cyber Physical System
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1