{"title":"Nuplex 80+:满足ALWR要求的进化方法","authors":"D. Harmon","doi":"10.1109/HFPP.1992.283438","DOIUrl":null,"url":null,"abstract":"Discusses how advanced light water reactors (ALWRs) requirements are met through an evolutionary design, the Nuplex 80+ ACC. The basis for the use of advances in implementation technology, data processing and man-machine interface (MMI) presentation techiques are provided. The Nuplex 80+ ACC is an evolutionary ALWR design meeting the requirements for advanced plants through MMI elements derived from current generation control rooms. The evolutionary design approach has balanced the tradeoffs between advances in implementation technology, data processing capability, and the man-machine interface with reliance on proven designs. The resulting design implements existing MMI functions to solve concerns with current generation designs and improve operability without significant change to current generation operations philosophies. Thus, the Nuplex 80+ ACC is the evolutionary control room complement to the System 80+ standard plant design.<<ETX>>","PeriodicalId":150946,"journal":{"name":"Conference Record for 1992 Fifth Conference on Human Factors and Power Plants","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Nuplex 80+: an evolutionary approach to meeting ALWR requirements\",\"authors\":\"D. Harmon\",\"doi\":\"10.1109/HFPP.1992.283438\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Discusses how advanced light water reactors (ALWRs) requirements are met through an evolutionary design, the Nuplex 80+ ACC. The basis for the use of advances in implementation technology, data processing and man-machine interface (MMI) presentation techiques are provided. The Nuplex 80+ ACC is an evolutionary ALWR design meeting the requirements for advanced plants through MMI elements derived from current generation control rooms. The evolutionary design approach has balanced the tradeoffs between advances in implementation technology, data processing capability, and the man-machine interface with reliance on proven designs. The resulting design implements existing MMI functions to solve concerns with current generation designs and improve operability without significant change to current generation operations philosophies. Thus, the Nuplex 80+ ACC is the evolutionary control room complement to the System 80+ standard plant design.<<ETX>>\",\"PeriodicalId\":150946,\"journal\":{\"name\":\"Conference Record for 1992 Fifth Conference on Human Factors and Power Plants\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-06-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record for 1992 Fifth Conference on Human Factors and Power Plants\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HFPP.1992.283438\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record for 1992 Fifth Conference on Human Factors and Power Plants","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HFPP.1992.283438","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

讨论了先进的轻水反应堆(alws)的要求是如何通过进化设计,Nuplex 80+ ACC来满足的。提供了利用先进的执行技术、数据处理和人机界面表示技术的基础。Nuplex 80+ ACC是一种进化的ALWR设计,通过从当前一代控制室衍生的MMI元素满足先进工厂的要求。进化式设计方法在实现技术、数据处理能力和依赖于经过验证的设计的人机界面之间取得了平衡。最终的设计实现了现有的MMI功能,以解决当前代设计的问题,并在不显著改变当前代操作理念的情况下提高可操作性。因此,Nuplex 80+ ACC是系统80+标准工厂设计的进化控制室补充。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Nuplex 80+: an evolutionary approach to meeting ALWR requirements
Discusses how advanced light water reactors (ALWRs) requirements are met through an evolutionary design, the Nuplex 80+ ACC. The basis for the use of advances in implementation technology, data processing and man-machine interface (MMI) presentation techiques are provided. The Nuplex 80+ ACC is an evolutionary ALWR design meeting the requirements for advanced plants through MMI elements derived from current generation control rooms. The evolutionary design approach has balanced the tradeoffs between advances in implementation technology, data processing capability, and the man-machine interface with reliance on proven designs. The resulting design implements existing MMI functions to solve concerns with current generation designs and improve operability without significant change to current generation operations philosophies. Thus, the Nuplex 80+ ACC is the evolutionary control room complement to the System 80+ standard plant design.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
When technicians use computer programs: approaches to procedure writing The evaluation of crew factors in aircrew team performance Performance of nuclear power plant or automated system depends on operator's availability Getting the attention of senior management for human factors issues: quantitative survey data Progress of I&C system and control room design in TEPCO nuclear power plants
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1