K. Fujita, K. Tamura, W. Kaneko, T. Morikawa, Linh Tuong Nguyen, H. Ishizawa, E. Toba
{"title":"基于光学传感和内标法的无创血糖测量技术","authors":"K. Fujita, K. Tamura, W. Kaneko, T. Morikawa, Linh Tuong Nguyen, H. Ishizawa, E. Toba","doi":"10.1109/SICE.2006.315304","DOIUrl":null,"url":null,"abstract":"This paper describes a new noninvasive measurement of blood glucose based on an optical sensing. This uses Fourier transform infrared spectroscopy of attenuated total reflection. In order to study the influence of individual difference, the internal standard method was introduced. This paper describes the detail of the internal standard method and its effect to the blood glucose calibration. Significant improvement was obtained by using the internal standard","PeriodicalId":244878,"journal":{"name":"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Noninvasive Measurement of Blood Glucose Based on Optical Sensing and Internal Standard Method\",\"authors\":\"K. Fujita, K. Tamura, W. Kaneko, T. Morikawa, Linh Tuong Nguyen, H. Ishizawa, E. Toba\",\"doi\":\"10.1109/SICE.2006.315304\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes a new noninvasive measurement of blood glucose based on an optical sensing. This uses Fourier transform infrared spectroscopy of attenuated total reflection. In order to study the influence of individual difference, the internal standard method was introduced. This paper describes the detail of the internal standard method and its effect to the blood glucose calibration. Significant improvement was obtained by using the internal standard\",\"PeriodicalId\":244878,\"journal\":{\"name\":\"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SICE.2006.315304\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SICE.2006.315304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Noninvasive Measurement of Blood Glucose Based on Optical Sensing and Internal Standard Method
This paper describes a new noninvasive measurement of blood glucose based on an optical sensing. This uses Fourier transform infrared spectroscopy of attenuated total reflection. In order to study the influence of individual difference, the internal standard method was introduced. This paper describes the detail of the internal standard method and its effect to the blood glucose calibration. Significant improvement was obtained by using the internal standard