对同步发电机定子漏抗测定的贡献

Z. De Grève, M. Delhaye, G. Lossa, F. Vallée
{"title":"对同步发电机定子漏抗测定的贡献","authors":"Z. De Grève, M. Delhaye, G. Lossa, F. Vallée","doi":"10.1109/ICIT.2013.6505686","DOIUrl":null,"url":null,"abstract":"In this paper, the limits and consequences of an algorithm proposed in for the determination of the stator leakage reactance of synchronous machines are highlighted. This method requires the recording of the stator voltage/current characteristic of the machine unloaded and unexcited, in addition with the classical open-circuit characteristic. This approach has been implemented in our applications but instability problems appeared during the unloaded and unexcited test. In order to overcome this limitation, the use of a well-known alternative test (the slip test) in specific conditions is proposed here. We applied it to two types of synchronous machines (salient and non-salient pole synchronous machines) and have reached reliable results. Finally, in order to judge the efficiency of the method proposed in front of measurement errors, a sensitivity analysis was also conducted.","PeriodicalId":192784,"journal":{"name":"2013 IEEE International Conference on Industrial Technology (ICIT)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Contribution to the determination of the stator leakage reactance of synchronous generators\",\"authors\":\"Z. De Grève, M. Delhaye, G. Lossa, F. Vallée\",\"doi\":\"10.1109/ICIT.2013.6505686\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the limits and consequences of an algorithm proposed in for the determination of the stator leakage reactance of synchronous machines are highlighted. This method requires the recording of the stator voltage/current characteristic of the machine unloaded and unexcited, in addition with the classical open-circuit characteristic. This approach has been implemented in our applications but instability problems appeared during the unloaded and unexcited test. In order to overcome this limitation, the use of a well-known alternative test (the slip test) in specific conditions is proposed here. We applied it to two types of synchronous machines (salient and non-salient pole synchronous machines) and have reached reliable results. Finally, in order to judge the efficiency of the method proposed in front of measurement errors, a sensitivity analysis was also conducted.\",\"PeriodicalId\":192784,\"journal\":{\"name\":\"2013 IEEE International Conference on Industrial Technology (ICIT)\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE International Conference on Industrial Technology (ICIT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIT.2013.6505686\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference on Industrial Technology (ICIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIT.2013.6505686","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在本文中,提出了一种算法的局限性和后果确定的同步电机定子漏抗突出。这种方法需要记录机器空载和无激励时的定子电压/电流特性,以及经典的开路特性。这种方法已经在我们的应用程序中实现了,但是在卸载和非激励测试期间出现了不稳定问题。为了克服这一限制,在这里建议在特定条件下使用一种众所周知的替代试验(滑移试验)。我们将其应用于两种类型的同步电机(凸极和非凸极同步电机),并取得了可靠的结果。最后,为了在测量误差面前判断所提出方法的有效性,还进行了灵敏度分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Contribution to the determination of the stator leakage reactance of synchronous generators
In this paper, the limits and consequences of an algorithm proposed in for the determination of the stator leakage reactance of synchronous machines are highlighted. This method requires the recording of the stator voltage/current characteristic of the machine unloaded and unexcited, in addition with the classical open-circuit characteristic. This approach has been implemented in our applications but instability problems appeared during the unloaded and unexcited test. In order to overcome this limitation, the use of a well-known alternative test (the slip test) in specific conditions is proposed here. We applied it to two types of synchronous machines (salient and non-salient pole synchronous machines) and have reached reliable results. Finally, in order to judge the efficiency of the method proposed in front of measurement errors, a sensitivity analysis was also conducted.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Low cost circular couplers for bi-directional IPT systems Performance evaluation of variable rates raptor codes in mobile WiMAX Improved non-ideality compensation for the V/f controlled permanent magnet synchronous motor Overview of helical foil winding design for planar magnetic components Tactile proximity sensors for robotic applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1