{"title":"光伏应用中不同冷却方案的比较","authors":"Feyzullah Behlül Ökkul, E. Kayabaşi, E. Çeli̇k, H. Kurt, E. Arcaklioğlu","doi":"10.1109/PVCON.2018.8523972","DOIUrl":null,"url":null,"abstract":"A temperature increase plays a negative role on photovoltaic (PV) panel conversion efficiency by increasing recombination rates. In this study, air- and water-cooling options were simulated to investigate the efficiency behavior of a specific PV panel made of heterojunction Silicon (Si) whilst PV panel was cooling in operation by using ANSYS-FLUENT. For air cooling, two different options were suggested: air cooling with four different flow speeds and air cooling with a heat sink addition with three different flow speeds. As for water-cooling three flowrates were considered. Temperature distributions of PV panels for the all cooling options were demonstrated as a function of flow velocity of air and flowrate of water for different cooling conditions and compared with each other. The influence of temperature difference on panel conversion efficiency were also discussed. As a result, heat sink with a proper flow arrangement cooling option showed the best performance in terms of minimum material, minimum cost and minimum complexity with the 42 °C, 38.4 °C, 35.9°C average surface temperatures and 20.9%, 21.3%, 21.5% panel efficiencies.","PeriodicalId":380858,"journal":{"name":"2018 International Conference on Photovoltaic Science and Technologies (PVCon)","volume":"126 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Comparison of Different Cooling Options for Photovoltaic Applications\",\"authors\":\"Feyzullah Behlül Ökkul, E. Kayabaşi, E. Çeli̇k, H. Kurt, E. Arcaklioğlu\",\"doi\":\"10.1109/PVCON.2018.8523972\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A temperature increase plays a negative role on photovoltaic (PV) panel conversion efficiency by increasing recombination rates. In this study, air- and water-cooling options were simulated to investigate the efficiency behavior of a specific PV panel made of heterojunction Silicon (Si) whilst PV panel was cooling in operation by using ANSYS-FLUENT. For air cooling, two different options were suggested: air cooling with four different flow speeds and air cooling with a heat sink addition with three different flow speeds. As for water-cooling three flowrates were considered. Temperature distributions of PV panels for the all cooling options were demonstrated as a function of flow velocity of air and flowrate of water for different cooling conditions and compared with each other. The influence of temperature difference on panel conversion efficiency were also discussed. As a result, heat sink with a proper flow arrangement cooling option showed the best performance in terms of minimum material, minimum cost and minimum complexity with the 42 °C, 38.4 °C, 35.9°C average surface temperatures and 20.9%, 21.3%, 21.5% panel efficiencies.\",\"PeriodicalId\":380858,\"journal\":{\"name\":\"2018 International Conference on Photovoltaic Science and Technologies (PVCon)\",\"volume\":\"126 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference on Photovoltaic Science and Technologies (PVCon)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PVCON.2018.8523972\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Photovoltaic Science and Technologies (PVCon)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PVCON.2018.8523972","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

温度升高会增加复合率,从而对光伏面板的转换效率产生负面影响。在本研究中,采用ANSYS-FLUENT软件模拟了空气和水冷却两种冷却方式,研究了异质结硅(Si)光伏板在运行冷却过程中的效率行为。对于风冷,提出了两种不同的选择:四种不同流速的风冷和三种不同流速的风冷散热器。对于水冷却,考虑了三种流量。在不同冷却条件下,光伏板的温度分布以空气流速和水流速的函数形式进行了演示,并进行了相互比较。讨论了温差对面板转换效率的影响。结果表明,在42°C、38.4°C、35.9°C的平均表面温度和20.9%、21.3%、21.5%的面板效率下,合理的散热方式在最小材料、最小成本和最小复杂性方面表现出最佳性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of Different Cooling Options for Photovoltaic Applications
A temperature increase plays a negative role on photovoltaic (PV) panel conversion efficiency by increasing recombination rates. In this study, air- and water-cooling options were simulated to investigate the efficiency behavior of a specific PV panel made of heterojunction Silicon (Si) whilst PV panel was cooling in operation by using ANSYS-FLUENT. For air cooling, two different options were suggested: air cooling with four different flow speeds and air cooling with a heat sink addition with three different flow speeds. As for water-cooling three flowrates were considered. Temperature distributions of PV panels for the all cooling options were demonstrated as a function of flow velocity of air and flowrate of water for different cooling conditions and compared with each other. The influence of temperature difference on panel conversion efficiency were also discussed. As a result, heat sink with a proper flow arrangement cooling option showed the best performance in terms of minimum material, minimum cost and minimum complexity with the 42 °C, 38.4 °C, 35.9°C average surface temperatures and 20.9%, 21.3%, 21.5% panel efficiencies.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Electro-Optical Analysis and Numerical Modeling of Cu2O as the Absorber Layer in Advanced Solar Cells Parameters Extraction of Single and Double Diode Model Using the Flower Algorithm Two-Dimensional Numerical Analysis of Phosphorus Diffused Emitters on Black Silicon Surfaces Experimental Evaluation of Performance Drop for Crystalline Photovoltaic Modules Affected by Snail Trails Defect The Feasibility of Photovoltaic and Grid-Hybrid Power Plant for Water Pumping Station in Tabriz-Iran
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1