{"title":"分析结构的节奏土地建设","authors":"Subhan Manthofani, Ari Firmanto","doi":"10.33603/jgst.v1i1.1037","DOIUrl":null,"url":null,"abstract":"Mundu is an area in the district of Cirebon that passed by the Pantura lane, in the area of the Mundu there are various kinds of trading industry, one of which is the trading industry from PT. TEMPO LAND that are producing medicines for health. In order to create a good production and marketing, so in the area is built office production and marketing of PT. TEMPO LAND. PT. TEMPO LAND is a group company in the form of by the TEMPO GROUP or PT. TEMPO SCAN PACIFIC Tbk . The company PT. TEMPO GROUP started its business on November 3, 1953. Production from this company produces a variety of pharmaceutical and healthcare products with different brands. In order to create a structure that is safe and meets serviceability limit, so in the process of design the building structure must be according to SNI - 2847 - 2013 of reinforced concrete, which is the latest regulations adapted from the latest material technology development refers to the AISC. Beside planning, the loading structure must be according to SNI – 1727 – 2013 , then for calculation of earthquake engineering refers to SNI – 1726 – 2012. Analysis structure using SAP2000, for the material of structures is used concrete including frame section (column, sloof, beam, and slab). And then the result from analysis are the PT. TEMPO LAND building is safe or not, with check the deflection and check load maximum permit from analysis foundation of PT. TEMPO LAND. Keywords : Analysis structure, SAP2000, frame section, deflection.","PeriodicalId":419103,"journal":{"name":"Journal of Green Science and Technology","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ANALYSIS STRUCTURE THE PT. TEMPO LAND BUILDING\",\"authors\":\"Subhan Manthofani, Ari Firmanto\",\"doi\":\"10.33603/jgst.v1i1.1037\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Mundu is an area in the district of Cirebon that passed by the Pantura lane, in the area of the Mundu there are various kinds of trading industry, one of which is the trading industry from PT. TEMPO LAND that are producing medicines for health. In order to create a good production and marketing, so in the area is built office production and marketing of PT. TEMPO LAND. PT. TEMPO LAND is a group company in the form of by the TEMPO GROUP or PT. TEMPO SCAN PACIFIC Tbk . The company PT. TEMPO GROUP started its business on November 3, 1953. Production from this company produces a variety of pharmaceutical and healthcare products with different brands. In order to create a structure that is safe and meets serviceability limit, so in the process of design the building structure must be according to SNI - 2847 - 2013 of reinforced concrete, which is the latest regulations adapted from the latest material technology development refers to the AISC. Beside planning, the loading structure must be according to SNI – 1727 – 2013 , then for calculation of earthquake engineering refers to SNI – 1726 – 2012. Analysis structure using SAP2000, for the material of structures is used concrete including frame section (column, sloof, beam, and slab). And then the result from analysis are the PT. TEMPO LAND building is safe or not, with check the deflection and check load maximum permit from analysis foundation of PT. TEMPO LAND. Keywords : Analysis structure, SAP2000, frame section, deflection.\",\"PeriodicalId\":419103,\"journal\":{\"name\":\"Journal of Green Science and Technology\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Green Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33603/jgst.v1i1.1037\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Green Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33603/jgst.v1i1.1037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
蒙都是Cirebon区的一个地区,经过Pantura巷,在蒙都地区有各种各样的贸易行业,其中之一是PT. TEMPO LAND的贸易行业,生产保健药物。为了创造一个良好的生产和营销,因此在该地区建立了PT. TEMPO LAND的生产和营销办公室。天宝置地是天宝集团或天宝SCAN PACIFIC Tbk旗下的集团公司。PT. TEMPO GROUP公司于1953年11月3日开始营业。该公司生产各种不同品牌的药品和保健品。为了创造一个既安全又符合使用极限的结构,所以在设计建筑结构的过程中必须按照SNI - 2847 - 2013的钢筋混凝土,这是最新的法规改编自最新的材料技术发展参考AISC。除规划外,荷载结构必须按SNI - 1727 - 2013计算,地震工程计算参照SNI - 1726 - 2012计算。结构分析采用SAP2000,结构材料采用混凝土,包括框架截面(柱、槽、梁、板)。在分析基础上进行了挠度校核和荷载最大允许校核,得出了PT. TEMPO LAND建筑物是否安全的分析结果。关键词:结构分析;SAP2000;框架截面;
Mundu is an area in the district of Cirebon that passed by the Pantura lane, in the area of the Mundu there are various kinds of trading industry, one of which is the trading industry from PT. TEMPO LAND that are producing medicines for health. In order to create a good production and marketing, so in the area is built office production and marketing of PT. TEMPO LAND. PT. TEMPO LAND is a group company in the form of by the TEMPO GROUP or PT. TEMPO SCAN PACIFIC Tbk . The company PT. TEMPO GROUP started its business on November 3, 1953. Production from this company produces a variety of pharmaceutical and healthcare products with different brands. In order to create a structure that is safe and meets serviceability limit, so in the process of design the building structure must be according to SNI - 2847 - 2013 of reinforced concrete, which is the latest regulations adapted from the latest material technology development refers to the AISC. Beside planning, the loading structure must be according to SNI – 1727 – 2013 , then for calculation of earthquake engineering refers to SNI – 1726 – 2012. Analysis structure using SAP2000, for the material of structures is used concrete including frame section (column, sloof, beam, and slab). And then the result from analysis are the PT. TEMPO LAND building is safe or not, with check the deflection and check load maximum permit from analysis foundation of PT. TEMPO LAND. Keywords : Analysis structure, SAP2000, frame section, deflection.