{"title":"基于低压法的电流互感器分析系统研究","authors":"Tianyu Liu, Tingtao Zuo, Fei Wang, Xiaoguang Hu","doi":"10.1109/ICIEA.2011.5975746","DOIUrl":null,"url":null,"abstract":"A new type of current transformer (CT) calibration approach is introduced, which is based on the current transformer equivalent model. We can analysis the CT's performance by calculating its internal parameters. The current transformer error, voltage characteristics, 10% error curve can be measured, solving the problem of up-flow unit and the standard current transformer is no longer needed in the on-site verification. It is more convenient for the users to carry out the field testing of current transformers.","PeriodicalId":304500,"journal":{"name":"2011 6th IEEE Conference on Industrial Electronics and Applications","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research of current transformer analyzing system based on low-voltage approach\",\"authors\":\"Tianyu Liu, Tingtao Zuo, Fei Wang, Xiaoguang Hu\",\"doi\":\"10.1109/ICIEA.2011.5975746\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new type of current transformer (CT) calibration approach is introduced, which is based on the current transformer equivalent model. We can analysis the CT's performance by calculating its internal parameters. The current transformer error, voltage characteristics, 10% error curve can be measured, solving the problem of up-flow unit and the standard current transformer is no longer needed in the on-site verification. It is more convenient for the users to carry out the field testing of current transformers.\",\"PeriodicalId\":304500,\"journal\":{\"name\":\"2011 6th IEEE Conference on Industrial Electronics and Applications\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 6th IEEE Conference on Industrial Electronics and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEA.2011.5975746\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 6th IEEE Conference on Industrial Electronics and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEA.2011.5975746","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research of current transformer analyzing system based on low-voltage approach
A new type of current transformer (CT) calibration approach is introduced, which is based on the current transformer equivalent model. We can analysis the CT's performance by calculating its internal parameters. The current transformer error, voltage characteristics, 10% error curve can be measured, solving the problem of up-flow unit and the standard current transformer is no longer needed in the on-site verification. It is more convenient for the users to carry out the field testing of current transformers.