Pablo Tupiza, Wilson Pavón, Dario Jaramillo, J. Muñoz, Carlos Barrera-Singaña, Myriam Tipan
{"title":"光伏发电统一有源滤波器降低总电流谐波失真策略","authors":"Pablo Tupiza, Wilson Pavón, Dario Jaramillo, J. Muñoz, Carlos Barrera-Singaña, Myriam Tipan","doi":"10.1109/GlobConHT56829.2023.10087658","DOIUrl":null,"url":null,"abstract":"This paper makes a proposal for a unified active power filter (UAPF) to reduce the total harmonic distortion (THD) in low voltage distribution networks. Thus, a photovoltaic (PV) generation is used as the UAPF's source, along with a boost converter. A non-linear load is in the seventh bus-bar of the IEEE 13-bar system, which serves as the test bench. discussing the effects of the system's voltage, current, and THD. As a result, the harmonics of the current (THDi) and voltage (THDv) decreased; they were reduced to 6 and 3 percentage points, respectively. The outcomes are within the parameters specified by the ARCERNNR -017/2020 resolution and IEEE 1159 standards.","PeriodicalId":355921,"journal":{"name":"2023 IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT)","volume":"130 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Strategy for Reducing Total Current Harmonics Distortion using an Unified Active Power Filter (UAPF) with Photovoltaic generation\",\"authors\":\"Pablo Tupiza, Wilson Pavón, Dario Jaramillo, J. Muñoz, Carlos Barrera-Singaña, Myriam Tipan\",\"doi\":\"10.1109/GlobConHT56829.2023.10087658\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper makes a proposal for a unified active power filter (UAPF) to reduce the total harmonic distortion (THD) in low voltage distribution networks. Thus, a photovoltaic (PV) generation is used as the UAPF's source, along with a boost converter. A non-linear load is in the seventh bus-bar of the IEEE 13-bar system, which serves as the test bench. discussing the effects of the system's voltage, current, and THD. As a result, the harmonics of the current (THDi) and voltage (THDv) decreased; they were reduced to 6 and 3 percentage points, respectively. The outcomes are within the parameters specified by the ARCERNNR -017/2020 resolution and IEEE 1159 standards.\",\"PeriodicalId\":355921,\"journal\":{\"name\":\"2023 IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT)\",\"volume\":\"130 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/GlobConHT56829.2023.10087658\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GlobConHT56829.2023.10087658","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Strategy for Reducing Total Current Harmonics Distortion using an Unified Active Power Filter (UAPF) with Photovoltaic generation
This paper makes a proposal for a unified active power filter (UAPF) to reduce the total harmonic distortion (THD) in low voltage distribution networks. Thus, a photovoltaic (PV) generation is used as the UAPF's source, along with a boost converter. A non-linear load is in the seventh bus-bar of the IEEE 13-bar system, which serves as the test bench. discussing the effects of the system's voltage, current, and THD. As a result, the harmonics of the current (THDi) and voltage (THDv) decreased; they were reduced to 6 and 3 percentage points, respectively. The outcomes are within the parameters specified by the ARCERNNR -017/2020 resolution and IEEE 1159 standards.