浸没固体合成孔径成像中的补偿传感器衍射效应

F. Lingvall, T. Stepinski
{"title":"浸没固体合成孔径成像中的补偿传感器衍射效应","authors":"F. Lingvall, T. Stepinski","doi":"10.1109/ULTSYM.2002.1193502","DOIUrl":null,"url":null,"abstract":"One of the fundamental requirements for the successful application of the classical synthetic aperture focusing technique (SAFT) is the use of a transducer that emits spherical (cylindrical) waves. For a planar transducer, the performance of the SAFT algorithm will deteriorate if its active area becomes too large comparing to the wavelength. This is due to the spatial impulse responses (SIRs) associated with the transducer that no longer resemble Dirac functions since the emitted waves is not spherical. Therefore, to achieve a high resolution or finite-sized transducers, the SIRs must be taken into consideration. Here, we propose a method that is based on a discrete linear model of the imaging system. The method uses a spatio-temporal deconvolution technique designed to minimize the mean squared reconstruction error of the imaging system. To demonstrate the performance of the proposed method we present experiments using a phased array for the inspection of a copper specimen. The results obtained using the deconvolution method for finite apertures are compared to those obtained with a time-domain SAFT algorithm and a focused phased array.","PeriodicalId":378705,"journal":{"name":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Compensating transducer diffraction effects in synthetic aperture imaging for immersed solids\",\"authors\":\"F. Lingvall, T. Stepinski\",\"doi\":\"10.1109/ULTSYM.2002.1193502\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One of the fundamental requirements for the successful application of the classical synthetic aperture focusing technique (SAFT) is the use of a transducer that emits spherical (cylindrical) waves. For a planar transducer, the performance of the SAFT algorithm will deteriorate if its active area becomes too large comparing to the wavelength. This is due to the spatial impulse responses (SIRs) associated with the transducer that no longer resemble Dirac functions since the emitted waves is not spherical. Therefore, to achieve a high resolution or finite-sized transducers, the SIRs must be taken into consideration. Here, we propose a method that is based on a discrete linear model of the imaging system. The method uses a spatio-temporal deconvolution technique designed to minimize the mean squared reconstruction error of the imaging system. To demonstrate the performance of the proposed method we present experiments using a phased array for the inspection of a copper specimen. The results obtained using the deconvolution method for finite apertures are compared to those obtained with a time-domain SAFT algorithm and a focused phased array.\",\"PeriodicalId\":378705,\"journal\":{\"name\":\"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.\",\"volume\":\"65 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2002.1193502\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2002.1193502","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

经典合成孔径聚焦技术(SAFT)成功应用的基本要求之一是使用发射球面(圆柱)波的换能器。对于平面换能器,如果其有效面积与波长相比过大,则会导致SAFT算法的性能下降。这是由于与换能器相关的空间脉冲响应(SIRs)不再像狄拉克函数,因为发射的波不是球形的。因此,为了实现高分辨率或有限尺寸的换能器,必须考虑到SIRs。在这里,我们提出了一种基于成像系统的离散线性模型的方法。该方法采用了一种时空反褶积技术,旨在使成像系统的均方重构误差最小化。为了证明所提出的方法的性能,我们提出了使用相控阵检查铜试样的实验。将有限孔径的反褶积方法与时域SAFT算法和聚焦相控阵的结果进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Compensating transducer diffraction effects in synthetic aperture imaging for immersed solids
One of the fundamental requirements for the successful application of the classical synthetic aperture focusing technique (SAFT) is the use of a transducer that emits spherical (cylindrical) waves. For a planar transducer, the performance of the SAFT algorithm will deteriorate if its active area becomes too large comparing to the wavelength. This is due to the spatial impulse responses (SIRs) associated with the transducer that no longer resemble Dirac functions since the emitted waves is not spherical. Therefore, to achieve a high resolution or finite-sized transducers, the SIRs must be taken into consideration. Here, we propose a method that is based on a discrete linear model of the imaging system. The method uses a spatio-temporal deconvolution technique designed to minimize the mean squared reconstruction error of the imaging system. To demonstrate the performance of the proposed method we present experiments using a phased array for the inspection of a copper specimen. The results obtained using the deconvolution method for finite apertures are compared to those obtained with a time-domain SAFT algorithm and a focused phased array.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of transducers arrays from piezoelectric hollow spheres Non-cylindrical transmission focusing for large depth of field Detection and mapping of thermal lesions using dual-mode ultrasound phased arrays Layered manufacturing for prototyping of novel transducers The effect of microbubble concentration on thresholds for tissue damage produced by single bursts of high intensity ultrasound during continuous Optison/spl reg/ infusion
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1