CAE接口与HP自动网络分析仪

S. Hamilton
{"title":"CAE接口与HP自动网络分析仪","authors":"S. Hamilton","doi":"10.1109/ARFTG.1985.323655","DOIUrl":null,"url":null,"abstract":"Recent enhancements in microwave simulator programs, such as EEsof's Touchstone, now permit the designer to use measured data to refine theoretical models. These models can now reflect manufacturing variables and non-ideal elements which will greatly enhance the predictability of future designs. The measured data is supplied through direct interaction with the HP 8510 or 3577 automatic network analyzers. Many exciting applications result -- active device characterization, de-embedding and component measurement for use in upgrading model parasitics to reflect the real world, to name a few. This paper presents the design of a 2 to 6 Ghz four-stage feedback amplifier to illustrate the power of the microwave simulator/automatic network analyzer interface.","PeriodicalId":371039,"journal":{"name":"26th ARFTG Conference Digest","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1985-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"CAE Interfaces with HP Automatic Network Analyzers\",\"authors\":\"S. Hamilton\",\"doi\":\"10.1109/ARFTG.1985.323655\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recent enhancements in microwave simulator programs, such as EEsof's Touchstone, now permit the designer to use measured data to refine theoretical models. These models can now reflect manufacturing variables and non-ideal elements which will greatly enhance the predictability of future designs. The measured data is supplied through direct interaction with the HP 8510 or 3577 automatic network analyzers. Many exciting applications result -- active device characterization, de-embedding and component measurement for use in upgrading model parasitics to reflect the real world, to name a few. This paper presents the design of a 2 to 6 Ghz four-stage feedback amplifier to illustrate the power of the microwave simulator/automatic network analyzer interface.\",\"PeriodicalId\":371039,\"journal\":{\"name\":\"26th ARFTG Conference Digest\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"26th ARFTG Conference Digest\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ARFTG.1985.323655\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"26th ARFTG Conference Digest","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARFTG.1985.323655","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

最近微波模拟器程序的改进,如EEsof的Touchstone,现在允许设计者使用测量数据来完善理论模型。这些模型现在可以反映制造变量和非理想元素,这将大大提高未来设计的可预测性。测量数据通过与HP 8510或3577自动网络分析仪直接交互提供。许多令人兴奋的应用结果-用于升级模型寄生以反映现实世界的有源器件表征,去嵌入和组件测量,仅举几例。本文设计了一个2 ~ 6ghz的四级反馈放大器,以说明微波模拟器/自动网络分析仪接口的功率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
CAE Interfaces with HP Automatic Network Analyzers
Recent enhancements in microwave simulator programs, such as EEsof's Touchstone, now permit the designer to use measured data to refine theoretical models. These models can now reflect manufacturing variables and non-ideal elements which will greatly enhance the predictability of future designs. The measured data is supplied through direct interaction with the HP 8510 or 3577 automatic network analyzers. Many exciting applications result -- active device characterization, de-embedding and component measurement for use in upgrading model parasitics to reflect the real world, to name a few. This paper presents the design of a 2 to 6 Ghz four-stage feedback amplifier to illustrate the power of the microwave simulator/automatic network analyzer interface.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Separation of Reflections for VSWR Measurements Improved Millimeter Waveguide Flanges Improve VANA Performance Instrument Test Cables Extend Measuring Ports of HP8510 VNA Calculaticn and Use of Time Domain Response From Vector Network Analyzer Measurements Gunn Diode Pulse Thermal Resistance and Characterization Test System
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1