{"title":"压痕加载过程中塑型化合物的塑性变形和破坏模式及其对粘接定量表征的重要性","authors":"N. Pflügler, G. M. Reuther, M. Goroll, R. Pufall, B. Wunderle","doi":"10.1109/EUROSIME.2019.8724566","DOIUrl":null,"url":null,"abstract":"Different test methods are used within the microelectronics community to quantify adhesion of material combinations interacting inside the package. Button Shear Tests or Bending Tests are popular test methods for studying moulding compound adhesion on various surfaces. The measured data obtained from these tests is a superposition of the characteristics of the interface, the experimental setup, and the test vehicle's geometry and materials used. Compressive contact, for example, between shear or bending tool and the sample might lead to plastic deformation. Nanoindentation on bulk moulding compound strips showed that plastic deformation under compressive loading does occur. Low indentation forces lead to a levelling of the rough surface. For higher forces residual imprints after indentation can be as deep as $15 \\mu \\mathrm {m}$. Test vehicles are very often only a few millimetres in size. Thus, sub-micron accuracy for displacement measurements becomes a necessity when extracting energies from force-displacement curves. Plastic deformation at the shear contact then needs to be subtracted from measurement data in order to achieve accurate adhesion results.","PeriodicalId":357224,"journal":{"name":"2019 20th International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems (EuroSimE)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Plastic deformation and failure modes of moulding compounds during indentation loading and their importance for the quantitative characterisation of adhesion\",\"authors\":\"N. Pflügler, G. M. Reuther, M. Goroll, R. Pufall, B. Wunderle\",\"doi\":\"10.1109/EUROSIME.2019.8724566\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Different test methods are used within the microelectronics community to quantify adhesion of material combinations interacting inside the package. Button Shear Tests or Bending Tests are popular test methods for studying moulding compound adhesion on various surfaces. The measured data obtained from these tests is a superposition of the characteristics of the interface, the experimental setup, and the test vehicle's geometry and materials used. Compressive contact, for example, between shear or bending tool and the sample might lead to plastic deformation. Nanoindentation on bulk moulding compound strips showed that plastic deformation under compressive loading does occur. Low indentation forces lead to a levelling of the rough surface. For higher forces residual imprints after indentation can be as deep as $15 \\\\mu \\\\mathrm {m}$. Test vehicles are very often only a few millimetres in size. Thus, sub-micron accuracy for displacement measurements becomes a necessity when extracting energies from force-displacement curves. Plastic deformation at the shear contact then needs to be subtracted from measurement data in order to achieve accurate adhesion results.\",\"PeriodicalId\":357224,\"journal\":{\"name\":\"2019 20th International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems (EuroSimE)\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 20th International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems (EuroSimE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUROSIME.2019.8724566\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 20th International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems (EuroSimE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUROSIME.2019.8724566","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

微电子界使用不同的测试方法来量化在封装内部相互作用的材料组合的粘附性。按钮剪切试验或弯曲试验是研究模塑复合材料在各种表面上粘附性的常用试验方法。从这些测试中获得的测量数据是界面特性、实验装置、测试车辆的几何形状和使用的材料的叠加。例如,剪切或弯曲工具与样品之间的压缩接触可能导致塑性变形。体模复合条上的纳米压痕表明,在压缩载荷作用下,复合条确实发生了塑性变形。低压痕力导致粗糙表面的平整。对于更高的力,压痕后的残余压痕可深至$15 \mu \ mathm {m}$。测试车辆的尺寸通常只有几毫米。因此,当从力-位移曲线中提取能量时,亚微米精度的位移测量成为必要。然后需要从测量数据中减去剪切接触处的塑性变形,以获得准确的粘附结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Plastic deformation and failure modes of moulding compounds during indentation loading and their importance for the quantitative characterisation of adhesion
Different test methods are used within the microelectronics community to quantify adhesion of material combinations interacting inside the package. Button Shear Tests or Bending Tests are popular test methods for studying moulding compound adhesion on various surfaces. The measured data obtained from these tests is a superposition of the characteristics of the interface, the experimental setup, and the test vehicle's geometry and materials used. Compressive contact, for example, between shear or bending tool and the sample might lead to plastic deformation. Nanoindentation on bulk moulding compound strips showed that plastic deformation under compressive loading does occur. Low indentation forces lead to a levelling of the rough surface. For higher forces residual imprints after indentation can be as deep as $15 \mu \mathrm {m}$. Test vehicles are very often only a few millimetres in size. Thus, sub-micron accuracy for displacement measurements becomes a necessity when extracting energies from force-displacement curves. Plastic deformation at the shear contact then needs to be subtracted from measurement data in order to achieve accurate adhesion results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A SPICE-based Transient Thermal-Electronic Model for LEDs Electromigration Effects in Corroded BGA Accelerated Pump Out Testing for Thermal Greases Effect of material properties on PCB frequencies in electronic control unit Simulative Comparison of Polymer and Ceramic Encapsulation on SiC-MOSFET Power Modules under Thermomechanical Load
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1