{"title":"循环负荷运行下地壁绝缘阻抗在线监测","authors":"S. Sundeep, I. Tsyokhla, J. Wang, A. Griffo","doi":"10.1049/icp.2021.1069","DOIUrl":null,"url":null,"abstract":"The paradigm shift in the operation of the adjustable speed drives operating under frequent start and stop instead of long continuous operation induces thermo-mechanical stress. This intermittent operation changes the operating temperature of the machine frequently, which results in uneven expansion/contraction of different materials. This difference causes stress which accelerates the ageing of the insulations. So far, the effect of thermal stress on the ageing phenomenon is well-known in the literature. However, the study of ageing process under thermo-mechanical stress is scant. To circumvent the unpredictable downtime due to the stress, continuous monitoring of insulation health is attracting more attention. This work aims to study the effect of thermomechanical stress on insulation by exposing 7 stators of 2.83 kW servomotor to thermal cycles under temperature-controlled environment. The degradation of insulation is continuously observed by measuring the groundwall capacitance. Results show that the capacitance varies along with the temperature, and both its average and the peak-to-peak variation decay with aging. Based on the experimental investigation, a mathematical model representing the ageing phenomenon of the winding insulation is proposed. The proposed model is based on the assumption that the observed changes in the insulation capacitance due to thermal aging are the result of internal chemical reactions which obey the Arrhenius law.","PeriodicalId":188371,"journal":{"name":"The 10th International Conference on Power Electronics, Machines and Drives (PEMD 2020)","volume":"84 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Online Monitoring of Ground-wall Insulation Impedance under Cyclic Load Operation\",\"authors\":\"S. Sundeep, I. Tsyokhla, J. Wang, A. Griffo\",\"doi\":\"10.1049/icp.2021.1069\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paradigm shift in the operation of the adjustable speed drives operating under frequent start and stop instead of long continuous operation induces thermo-mechanical stress. This intermittent operation changes the operating temperature of the machine frequently, which results in uneven expansion/contraction of different materials. This difference causes stress which accelerates the ageing of the insulations. So far, the effect of thermal stress on the ageing phenomenon is well-known in the literature. However, the study of ageing process under thermo-mechanical stress is scant. To circumvent the unpredictable downtime due to the stress, continuous monitoring of insulation health is attracting more attention. This work aims to study the effect of thermomechanical stress on insulation by exposing 7 stators of 2.83 kW servomotor to thermal cycles under temperature-controlled environment. The degradation of insulation is continuously observed by measuring the groundwall capacitance. Results show that the capacitance varies along with the temperature, and both its average and the peak-to-peak variation decay with aging. Based on the experimental investigation, a mathematical model representing the ageing phenomenon of the winding insulation is proposed. The proposed model is based on the assumption that the observed changes in the insulation capacitance due to thermal aging are the result of internal chemical reactions which obey the Arrhenius law.\",\"PeriodicalId\":188371,\"journal\":{\"name\":\"The 10th International Conference on Power Electronics, Machines and Drives (PEMD 2020)\",\"volume\":\"84 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The 10th International Conference on Power Electronics, Machines and Drives (PEMD 2020)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1049/icp.2021.1069\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 10th International Conference on Power Electronics, Machines and Drives (PEMD 2020)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/icp.2021.1069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在频繁启动和停止而不是长时间连续运行的情况下运行的可调速驱动器的模式转换引起了热机械应力。这种间歇操作频繁改变机器的工作温度,导致不同物料的膨胀/收缩不均匀。这种差异造成压力,加速了绝缘材料的老化。到目前为止,热应力对老化现象的影响在文献中是众所周知的。然而,对热机械应力作用下的老化过程的研究却很少。为了避免由于应力导致的不可预测的停机时间,对绝缘健康状况的持续监测越来越受到人们的关注。本文通过将2.83 kW伺服电机的7个定子置于温控环境下进行热循环,研究热机械应力对绝缘的影响。通过测量地壁电容,可以连续观察到绝缘的退化。结果表明,电容随温度变化,其平均值和峰间变化随老化而衰减。在实验研究的基础上,提出了描述绕组绝缘老化现象的数学模型。所提出的模型是基于这样一个假设,即观察到的由于热老化引起的绝缘电容的变化是内部化学反应的结果,这些化学反应遵循阿伦尼乌斯定律。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Online Monitoring of Ground-wall Insulation Impedance under Cyclic Load Operation
The paradigm shift in the operation of the adjustable speed drives operating under frequent start and stop instead of long continuous operation induces thermo-mechanical stress. This intermittent operation changes the operating temperature of the machine frequently, which results in uneven expansion/contraction of different materials. This difference causes stress which accelerates the ageing of the insulations. So far, the effect of thermal stress on the ageing phenomenon is well-known in the literature. However, the study of ageing process under thermo-mechanical stress is scant. To circumvent the unpredictable downtime due to the stress, continuous monitoring of insulation health is attracting more attention. This work aims to study the effect of thermomechanical stress on insulation by exposing 7 stators of 2.83 kW servomotor to thermal cycles under temperature-controlled environment. The degradation of insulation is continuously observed by measuring the groundwall capacitance. Results show that the capacitance varies along with the temperature, and both its average and the peak-to-peak variation decay with aging. Based on the experimental investigation, a mathematical model representing the ageing phenomenon of the winding insulation is proposed. The proposed model is based on the assumption that the observed changes in the insulation capacitance due to thermal aging are the result of internal chemical reactions which obey the Arrhenius law.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A NEW FOUR-QUADRANT INVERTER BASED ON DUAL-WINDING ISOLATED CUK CONVERTERS FOR RAILWAY AND RENEWABLE ENERGY APPLICATIONS PERMANENT MAGNET SYNCHRONOUS MACHINE TEMPERATURE ESTIMATION USING LOW-ORDER LUMPED-PARAMETER THERMAL NETWORK WITH EXTENDED IRON LOSS MODEL THERMAL DC TEST AND ANALYSIS OF A STATOR MADE WITH RESIN TRICKLE IMPREGNATION OPTIMISATION OF THE GATE VOLTAGE IN SiC MOSFETS: EFFICIENCY VS RELIABILITY AN EXPERIMENTAL COMPARISON OF THERMAL MODELLING TECHNIQUES FOR IGBT MODULES IN ELECTRICAL DRIVETRAINS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1