{"title":"直角z形肋的矩形管道强化传热","authors":"M. Pimsarn, Parkpoom Sriromreun, P. Promvonge","doi":"10.1109/ESD.2010.5598858","DOIUrl":null,"url":null,"abstract":"An experiment is focused on the design of the suitable ribs used for enhancing heat transfer in a rectangular duct heat exchanger by using wall heat transfer (Nusselt number), friction loss (friction factor) and thermal performance (thermal enhancement factor) data. The Z-shaped ribs were set on the rectangular duct at 30°, 45° and 60° and flat rib was set at 90° relative to the air flow direction. Reynolds numbers studied ranging from 5000 to 25,000 in the test section. The rectangular duct has aspect ratio, AR = 10 and height, H = 30 mm with the Z-rib height (e), e/H = 0.2 and the rib pitch (P), P/H = 3. The ribs were fitted in Z-shape (Z-rib) aligned in series on the whole area of the upper plate. The results of the Z-ribs show the significant increase in heat transfer rate and friction loss over the smooth channel. The 45° Z-rib provides the highest increase in the heat transfer rate and the best thermal performance","PeriodicalId":272782,"journal":{"name":"Proceedings of the International Conference on Energy and Sustainable Development: Issues and Strategies (ESD 2010)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"Augmented heat transfer in rectangular duct with angled Z-shaped ribs\",\"authors\":\"M. Pimsarn, Parkpoom Sriromreun, P. Promvonge\",\"doi\":\"10.1109/ESD.2010.5598858\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An experiment is focused on the design of the suitable ribs used for enhancing heat transfer in a rectangular duct heat exchanger by using wall heat transfer (Nusselt number), friction loss (friction factor) and thermal performance (thermal enhancement factor) data. The Z-shaped ribs were set on the rectangular duct at 30°, 45° and 60° and flat rib was set at 90° relative to the air flow direction. Reynolds numbers studied ranging from 5000 to 25,000 in the test section. The rectangular duct has aspect ratio, AR = 10 and height, H = 30 mm with the Z-rib height (e), e/H = 0.2 and the rib pitch (P), P/H = 3. The ribs were fitted in Z-shape (Z-rib) aligned in series on the whole area of the upper plate. The results of the Z-ribs show the significant increase in heat transfer rate and friction loss over the smooth channel. The 45° Z-rib provides the highest increase in the heat transfer rate and the best thermal performance\",\"PeriodicalId\":272782,\"journal\":{\"name\":\"Proceedings of the International Conference on Energy and Sustainable Development: Issues and Strategies (ESD 2010)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the International Conference on Energy and Sustainable Development: Issues and Strategies (ESD 2010)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESD.2010.5598858\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the International Conference on Energy and Sustainable Development: Issues and Strategies (ESD 2010)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESD.2010.5598858","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Augmented heat transfer in rectangular duct with angled Z-shaped ribs
An experiment is focused on the design of the suitable ribs used for enhancing heat transfer in a rectangular duct heat exchanger by using wall heat transfer (Nusselt number), friction loss (friction factor) and thermal performance (thermal enhancement factor) data. The Z-shaped ribs were set on the rectangular duct at 30°, 45° and 60° and flat rib was set at 90° relative to the air flow direction. Reynolds numbers studied ranging from 5000 to 25,000 in the test section. The rectangular duct has aspect ratio, AR = 10 and height, H = 30 mm with the Z-rib height (e), e/H = 0.2 and the rib pitch (P), P/H = 3. The ribs were fitted in Z-shape (Z-rib) aligned in series on the whole area of the upper plate. The results of the Z-ribs show the significant increase in heat transfer rate and friction loss over the smooth channel. The 45° Z-rib provides the highest increase in the heat transfer rate and the best thermal performance