Riska Fitriani, Kadek Subagiada, S. Muliyono, Robert Janssen Stevenly, Suryaningsih Suryaningsih
{"title":"Analisis Penggunaan Bolus Berbahan Plastisin pada Pasien Fibrosarcoma dengan Treatment Planning System (TPS)","authors":"Riska Fitriani, Kadek Subagiada, S. Muliyono, Robert Janssen Stevenly, Suryaningsih Suryaningsih","doi":"10.30872/ppj.v3i1.818","DOIUrl":null,"url":null,"abstract":"Bolus is a material that has properties similar to body tissues and is used to maximize the absorbed dose on the skin surface. The purpose of this research was to determine the most optimal treatment to kill fibrosarcoma on the patient’s skin surface by comparing the isodose curve and the value of the radiation absorption dose on the physical bolus (from CT-Scan) and model bolus (TPS). This study used data in the form of bolus images (with a bolus thickness of 0 cm, 0.5 cm and 1.0 cm) and phantom image. Then the data was processed with Treatment Planning System (TPS) and given energy variations in the form of electrons (10 MeV, 12 MeV, dan 15 MeV) and photons (6 MV and 10 MV). The result of this research was an isodosis curve that describes the distribution of the dose and the value of the absorbed dose of radiation received by the skin surface. The conclusion of this research is a bolus thickness of 0,5 cm and an electron energy of 15 MeV, has more even isodose curve (covering the entire tumor) and the maximum absorption dose value were 5720 cGy for physical bolus and 5710 cGy for TPS bolus.","PeriodicalId":221598,"journal":{"name":"Progressive Physics Journal","volume":"71 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progressive Physics Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30872/ppj.v3i1.818","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

Bolus是一种具有类似身体组织特性的材料,用于最大限度地提高皮肤表面的吸收剂量。本研究的目的是通过比较物理丸(ct扫描)和模型丸(TPS)的等剂量曲线和辐射吸收剂量值,确定杀死患者皮肤表面纤维肉瘤的最佳治疗方法。本研究使用的数据采用丸状图像(丸状厚度分别为0 cm、0.5 cm和1.0 cm)和幻像的形式。然后用处理计划系统(TPS)对数据进行处理,并给出电子(10 MeV、12 MeV、15 MeV)和光子(6 MV和10 MV)的能量变化形式。这项研究的结果是一个isoisosis曲线,描述了剂量的分布和皮肤表面接受的辐射吸收剂量的值。本研究结论为:药丸厚度为0.05 cm,电子能量为15 MeV,等剂量曲线更为均匀(覆盖整个肿瘤),物理药丸的最大吸收剂量值为5720 cGy, TPS药丸的最大吸收剂量值为5710 cGy。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analisis Penggunaan Bolus Berbahan Plastisin pada Pasien Fibrosarcoma dengan Treatment Planning System (TPS)
Bolus is a material that has properties similar to body tissues and is used to maximize the absorbed dose on the skin surface. The purpose of this research was to determine the most optimal treatment to kill fibrosarcoma on the patient’s skin surface by comparing the isodose curve and the value of the radiation absorption dose on the physical bolus (from CT-Scan) and model bolus (TPS). This study used data in the form of bolus images (with a bolus thickness of 0 cm, 0.5 cm and 1.0 cm) and phantom image. Then the data was processed with Treatment Planning System (TPS) and given energy variations in the form of electrons (10 MeV, 12 MeV, dan 15 MeV) and photons (6 MV and 10 MV). The result of this research was an isodosis curve that describes the distribution of the dose and the value of the absorbed dose of radiation received by the skin surface. The conclusion of this research is a bolus thickness of 0,5 cm and an electron energy of 15 MeV, has more even isodose curve (covering the entire tumor) and the maximum absorption dose value were 5720 cGy for physical bolus and 5710 cGy for TPS bolus.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analisis Perubahan Sinyal Pneumatic to Electric Menggunakan Algoritma Fuzzy Logic Kaitan Luas Permukaan Pot Bonang Dengan Frekuensi Nada Dasar Yang Dibangkitkan Penentuan Kedalaman dan Sudut Kemiringan Sesar Grindulu di Pacitan Menggunakan Metode Crow Search Algorithm (CSA) pada Data Self-Potential (SP) ANALISIS ISODOSIS TEKNIK TIGA DIMENSI DENGAN LAPANGAN KRANIOSPINAL PADA PASIEN ANAK Penilaian Tingkat Risiko Postur Kerja Menggunakan Metode REBA dan Biomekanika Pada Aktivitas Mengangkat Beban
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1