{"title":"附加机械传感器数据对基于肌电图的模式识别系统的影响","authors":"John A. Spanias, A. M. Simon, Kimberly A. Ingraham, L. Hargrove","doi":"10.1109/NER.2015.7146704","DOIUrl":null,"url":null,"abstract":"Powered lower limb prostheses can improve amputees' ability to traverse stairs and ramps by providing positive mechanical work at the knee and ankle joint. EMG signals have been proposed as one way of providing seamless mode transitions by using them in combination with embedded mechanical sensors as inputs to a pattern recognition system that predicts the user's desired locomotion mode. In this study, we have expanded the amount of mechanical sensor information to include data from an additional five degrees of freedom in the load cell, as well as calculated thigh and shank angles. The purpose of this study was to determine the impact of this additional information on the performance of an EMG-based pattern recognition system designed to predict the desired locomotion mode. Our results indicate that including the additional mechanical sensor signals decreased the error rates of the system for both steady-state and transitional steps when compared to the reduced sensor set. We also found that EMG still decreased the error rate of the system, but to a lesser extent when using the additional mechanical sensors.","PeriodicalId":137451,"journal":{"name":"2015 7th International IEEE/EMBS Conference on Neural Engineering (NER)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"40","resultStr":"{\"title\":\"Effect of additional mechanical sensor data on an EMG-based pattern recognition system for a powered leg prosthesis\",\"authors\":\"John A. Spanias, A. M. Simon, Kimberly A. Ingraham, L. Hargrove\",\"doi\":\"10.1109/NER.2015.7146704\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Powered lower limb prostheses can improve amputees' ability to traverse stairs and ramps by providing positive mechanical work at the knee and ankle joint. EMG signals have been proposed as one way of providing seamless mode transitions by using them in combination with embedded mechanical sensors as inputs to a pattern recognition system that predicts the user's desired locomotion mode. In this study, we have expanded the amount of mechanical sensor information to include data from an additional five degrees of freedom in the load cell, as well as calculated thigh and shank angles. The purpose of this study was to determine the impact of this additional information on the performance of an EMG-based pattern recognition system designed to predict the desired locomotion mode. Our results indicate that including the additional mechanical sensor signals decreased the error rates of the system for both steady-state and transitional steps when compared to the reduced sensor set. We also found that EMG still decreased the error rate of the system, but to a lesser extent when using the additional mechanical sensors.\",\"PeriodicalId\":137451,\"journal\":{\"name\":\"2015 7th International IEEE/EMBS Conference on Neural Engineering (NER)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-04-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"40\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 7th International IEEE/EMBS Conference on Neural Engineering (NER)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NER.2015.7146704\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 7th International IEEE/EMBS Conference on Neural Engineering (NER)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NER.2015.7146704","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 40

摘要

动力下肢假肢可以通过在膝关节和踝关节处提供积极的机械功来提高截肢者通过楼梯和坡道的能力。EMG信号已经被提出作为一种提供无缝模式转换的方法,通过将它们与嵌入式机械传感器结合使用,作为预测用户所需运动模式的模式识别系统的输入。在这项研究中,我们扩大了机械传感器信息的数量,包括来自称重传感器中另外五个自由度的数据,以及计算的大腿和小腿角度。本研究的目的是确定这些附加信息对基于肌电图的模式识别系统性能的影响,该系统旨在预测期望的运动模式。我们的研究结果表明,与减少的传感器集相比,加入额外的机械传感器信号降低了系统在稳态和过渡阶段的错误率。我们还发现肌电图仍然降低了系统的错误率,但在使用额外的机械传感器时,其程度较小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of additional mechanical sensor data on an EMG-based pattern recognition system for a powered leg prosthesis
Powered lower limb prostheses can improve amputees' ability to traverse stairs and ramps by providing positive mechanical work at the knee and ankle joint. EMG signals have been proposed as one way of providing seamless mode transitions by using them in combination with embedded mechanical sensors as inputs to a pattern recognition system that predicts the user's desired locomotion mode. In this study, we have expanded the amount of mechanical sensor information to include data from an additional five degrees of freedom in the load cell, as well as calculated thigh and shank angles. The purpose of this study was to determine the impact of this additional information on the performance of an EMG-based pattern recognition system designed to predict the desired locomotion mode. Our results indicate that including the additional mechanical sensor signals decreased the error rates of the system for both steady-state and transitional steps when compared to the reduced sensor set. We also found that EMG still decreased the error rate of the system, but to a lesser extent when using the additional mechanical sensors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
iNODE in-vivo testing for selective vagus nerve recording and stimulation Computational studies on urinary bladder smooth muscle: Modeling ion channels and their role in generating electrical activity Fast calibration of a thirteen-command BCI by simulating SSVEPs from trains of transient VEPs - towards time-domain SSVEP BCI paradigms A hybrid NMES-exoskeleton for real objects interaction Computationally efficient, configurable, causal, real-time phase detection applied to local field potential oscillations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1