{"title":"开关冲击电压下绝缘厚度对油纸绝缘劣化特性的影响","authors":"C. Guo, Zhi Yang, Heli Ni, Rui Zhang, Yi Zhao, M. Jin, Qiaogen Zhang","doi":"10.1109/eic47619.2020.9158699","DOIUrl":null,"url":null,"abstract":"Oil immersed inverted current transformer is vulnerable to overvoltage in the transmission line during operation. The accumulative effect of switching impulse voltage can degrade the main insulation and lead to a reduction in insulating property. In order to investigate the deterioration characteristic of main insulation of oil immersed inverted current transformer under the accumulative effect of switching impulse voltage and indicate the insulation deterioration, we studied the E-N characteristic of oil-paper insulation with different thickness and gave corresponding semi-empirical formulation to characterize the deterioration characteristic of main insulation of oil immersed inverted current transformer. The influence of insulation thickness on insulation deterioration of oil paper was studied as well. The results show that, the oil-paper insulation has a significant accumulative effect under switching impulse voltage. The E-N characteristic of oil-paper insulation conforms to power exponential distribution. With the increase of insulation thickness, the single minimum breakdown electric field strength decreases gradually.","PeriodicalId":286019,"journal":{"name":"2020 IEEE Electrical Insulation Conference (EIC)","volume":"108 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Effect of Insulation Thickness on Deterioration Characteristics of Oil-Paper Insulation under Switching Impulse Voltage\",\"authors\":\"C. Guo, Zhi Yang, Heli Ni, Rui Zhang, Yi Zhao, M. Jin, Qiaogen Zhang\",\"doi\":\"10.1109/eic47619.2020.9158699\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Oil immersed inverted current transformer is vulnerable to overvoltage in the transmission line during operation. The accumulative effect of switching impulse voltage can degrade the main insulation and lead to a reduction in insulating property. In order to investigate the deterioration characteristic of main insulation of oil immersed inverted current transformer under the accumulative effect of switching impulse voltage and indicate the insulation deterioration, we studied the E-N characteristic of oil-paper insulation with different thickness and gave corresponding semi-empirical formulation to characterize the deterioration characteristic of main insulation of oil immersed inverted current transformer. The influence of insulation thickness on insulation deterioration of oil paper was studied as well. The results show that, the oil-paper insulation has a significant accumulative effect under switching impulse voltage. The E-N characteristic of oil-paper insulation conforms to power exponential distribution. With the increase of insulation thickness, the single minimum breakdown electric field strength decreases gradually.\",\"PeriodicalId\":286019,\"journal\":{\"name\":\"2020 IEEE Electrical Insulation Conference (EIC)\",\"volume\":\"108 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE Electrical Insulation Conference (EIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/eic47619.2020.9158699\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/eic47619.2020.9158699","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Effect of Insulation Thickness on Deterioration Characteristics of Oil-Paper Insulation under Switching Impulse Voltage
Oil immersed inverted current transformer is vulnerable to overvoltage in the transmission line during operation. The accumulative effect of switching impulse voltage can degrade the main insulation and lead to a reduction in insulating property. In order to investigate the deterioration characteristic of main insulation of oil immersed inverted current transformer under the accumulative effect of switching impulse voltage and indicate the insulation deterioration, we studied the E-N characteristic of oil-paper insulation with different thickness and gave corresponding semi-empirical formulation to characterize the deterioration characteristic of main insulation of oil immersed inverted current transformer. The influence of insulation thickness on insulation deterioration of oil paper was studied as well. The results show that, the oil-paper insulation has a significant accumulative effect under switching impulse voltage. The E-N characteristic of oil-paper insulation conforms to power exponential distribution. With the increase of insulation thickness, the single minimum breakdown electric field strength decreases gradually.