Dania Puspa Anggraini, Edi Sulistio Budi, Achmad Komarudin
{"title":"PID控制系统使用PLC CP1H流体级应用程序为最小","authors":"Dania Puspa Anggraini, Edi Sulistio Budi, Achmad Komarudin","doi":"10.33795/elk.v9i1.441","DOIUrl":null,"url":null,"abstract":"Dalam miniplant menggunakan sensor ultrasonic HC-SR04 yang digunakan untuk mengukur ketinggian air dalam tanki. Kendali Proportional Integral Derivative pada sistem ini telah diuji menggunakan 2 metode yaitu metode Ziegler Nichols dan metode Trial and Error. Dalam pengujian menggunakan 2 metode tersebut, hasil yang diperoleh dapat dianalisa bahwa dengan metode Trial and Error yang dapat menghasilkan sinyal respon dengan rise time 250s, overshoot 2.5% dan settling time 200s dengan parameter Kp = 10, Ti = 10 dan Td = 30.","PeriodicalId":345935,"journal":{"name":"Jurnal Elektronika dan Otomasi Industri","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"SISTEM KENDALI PID MENGGUNAKAN PLC CP1H APLIKASI LEVEL CAIRAN SEBAGAI MINIPLANT\",\"authors\":\"Dania Puspa Anggraini, Edi Sulistio Budi, Achmad Komarudin\",\"doi\":\"10.33795/elk.v9i1.441\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Dalam miniplant menggunakan sensor ultrasonic HC-SR04 yang digunakan untuk mengukur ketinggian air dalam tanki. Kendali Proportional Integral Derivative pada sistem ini telah diuji menggunakan 2 metode yaitu metode Ziegler Nichols dan metode Trial and Error. Dalam pengujian menggunakan 2 metode tersebut, hasil yang diperoleh dapat dianalisa bahwa dengan metode Trial and Error yang dapat menghasilkan sinyal respon dengan rise time 250s, overshoot 2.5% dan settling time 200s dengan parameter Kp = 10, Ti = 10 dan Td = 30.\",\"PeriodicalId\":345935,\"journal\":{\"name\":\"Jurnal Elektronika dan Otomasi Industri\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Elektronika dan Otomasi Industri\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33795/elk.v9i1.441\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Elektronika dan Otomasi Industri","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33795/elk.v9i1.441","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
SISTEM KENDALI PID MENGGUNAKAN PLC CP1H APLIKASI LEVEL CAIRAN SEBAGAI MINIPLANT
Dalam miniplant menggunakan sensor ultrasonic HC-SR04 yang digunakan untuk mengukur ketinggian air dalam tanki. Kendali Proportional Integral Derivative pada sistem ini telah diuji menggunakan 2 metode yaitu metode Ziegler Nichols dan metode Trial and Error. Dalam pengujian menggunakan 2 metode tersebut, hasil yang diperoleh dapat dianalisa bahwa dengan metode Trial and Error yang dapat menghasilkan sinyal respon dengan rise time 250s, overshoot 2.5% dan settling time 200s dengan parameter Kp = 10, Ti = 10 dan Td = 30.