太阳能变速功率因数校正无刷直流电机驱动

Muhammed P. P. Rajees, J. Rocky
{"title":"太阳能变速功率因数校正无刷直流电机驱动","authors":"Muhammed P. P. Rajees, J. Rocky","doi":"10.1109/ICEDSS.2016.7587793","DOIUrl":null,"url":null,"abstract":"Renewable energy sources have more importance. This importance is mainly because of limited resource and environmental problems of the conventional energy. Among the all renewable energy resources available, solar energy seems to be a major competitor as it is abundant in nature and also pollution-free. And we can convert this dc from solar panel to single phase AC source by using single phase inverter. This AC source is the supply for BLDC motor drive. And speed control method of BLDC motor with low cost for low power applications can be done by using a power factor corrected bridgeless buck-boost converter. Speed control is by controlling the dc link voltage of the voltage source inverter (VSI). Bridgeless converter reduces the conduction losses in the diode bridge rectifier. Commutation of the BLDC motor is by using VSI, which reduces the switching losses and it avoid the sparking and wear and tear by mechanical commutation and it is known as electronic commutation. Power factor improvement is done by designing the converter in discontinuous inductor current mode (DCM). As compared with other speed controlling method, speed control of BLDC motor by power factor corrected bridge less buck-boost convertor uses reduced number of components. This method has high efficiency and low cost as compared with other speed controlling method of BLDC motor and improved power quality is also achieved.","PeriodicalId":399107,"journal":{"name":"2016 Conference on Emerging Devices and Smart Systems (ICEDSS)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Solar Powered Variable Speed Power Factor Corrected BLDC Motor drive\",\"authors\":\"Muhammed P. P. Rajees, J. Rocky\",\"doi\":\"10.1109/ICEDSS.2016.7587793\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Renewable energy sources have more importance. This importance is mainly because of limited resource and environmental problems of the conventional energy. Among the all renewable energy resources available, solar energy seems to be a major competitor as it is abundant in nature and also pollution-free. And we can convert this dc from solar panel to single phase AC source by using single phase inverter. This AC source is the supply for BLDC motor drive. And speed control method of BLDC motor with low cost for low power applications can be done by using a power factor corrected bridgeless buck-boost converter. Speed control is by controlling the dc link voltage of the voltage source inverter (VSI). Bridgeless converter reduces the conduction losses in the diode bridge rectifier. Commutation of the BLDC motor is by using VSI, which reduces the switching losses and it avoid the sparking and wear and tear by mechanical commutation and it is known as electronic commutation. Power factor improvement is done by designing the converter in discontinuous inductor current mode (DCM). As compared with other speed controlling method, speed control of BLDC motor by power factor corrected bridge less buck-boost convertor uses reduced number of components. This method has high efficiency and low cost as compared with other speed controlling method of BLDC motor and improved power quality is also achieved.\",\"PeriodicalId\":399107,\"journal\":{\"name\":\"2016 Conference on Emerging Devices and Smart Systems (ICEDSS)\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-03-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 Conference on Emerging Devices and Smart Systems (ICEDSS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEDSS.2016.7587793\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Conference on Emerging Devices and Smart Systems (ICEDSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEDSS.2016.7587793","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

可再生能源更加重要。这种重要性主要是因为传统能源的资源有限和环境问题。在所有可用的可再生能源中,太阳能似乎是一个主要的竞争对手,因为它储量丰富,而且无污染。我们可以利用单相逆变器将太阳能板上的直流电转换成单相交流电源。这个交流电源是无刷直流电机驱动的电源。采用功率因数校正的无桥降压-升压变换器可以实现低成本低功耗无刷直流电机的调速方法。速度控制是通过控制电压源逆变器(VSI)的直流链路电压实现的。无桥变换器降低了二极管桥式整流器的导通损耗。无刷直流电机的换向是通过VSI来实现的,它既减少了开关损耗,又避免了机械换向产生的火花和磨损,被称为电子换向。通过将变换器设计成不连续电感电流模式(DCM)来改善功率因数。与其他调速方法相比,采用功率因数校正的无桥降压变换器对无刷直流电机进行调速,减少了元件数量。与其它无刷直流电机调速方法相比,该方法具有效率高、成本低、电能质量提高等优点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Solar Powered Variable Speed Power Factor Corrected BLDC Motor drive
Renewable energy sources have more importance. This importance is mainly because of limited resource and environmental problems of the conventional energy. Among the all renewable energy resources available, solar energy seems to be a major competitor as it is abundant in nature and also pollution-free. And we can convert this dc from solar panel to single phase AC source by using single phase inverter. This AC source is the supply for BLDC motor drive. And speed control method of BLDC motor with low cost for low power applications can be done by using a power factor corrected bridgeless buck-boost converter. Speed control is by controlling the dc link voltage of the voltage source inverter (VSI). Bridgeless converter reduces the conduction losses in the diode bridge rectifier. Commutation of the BLDC motor is by using VSI, which reduces the switching losses and it avoid the sparking and wear and tear by mechanical commutation and it is known as electronic commutation. Power factor improvement is done by designing the converter in discontinuous inductor current mode (DCM). As compared with other speed controlling method, speed control of BLDC motor by power factor corrected bridge less buck-boost convertor uses reduced number of components. This method has high efficiency and low cost as compared with other speed controlling method of BLDC motor and improved power quality is also achieved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Identification of most preferential denoising method for mammogram images Identification of leaf diseases in pepper plants using soft computing techniques Sliding-mode and fuzzy-logic adaptation mechanism for MRAS sensorless Vector Controlled Induction Motor with temperature monitoring Design and analysis of Phase Locked Loop for low power wireless applications Optimized method for compressive sensing in mobile environment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1