{"title":"一种实用的天线校准方法","authors":"B. Prakash, K. Suresh","doi":"10.1109/ICEMIC.1999.871640","DOIUrl":null,"url":null,"abstract":"Calibrated antennas are must for a certified EMC laboratory. A study has been conducted for calibrating antennas in the frequency range 200 MHz-1 GHz, which are needed for 1 meter radiated emission testing-RE02 of MIL-STD-461C. Measurements were conducted to ascertain the antenna factor for conical log spiral antenna by adapting 'Identical Two Antenna Method of calibration'. These measurements were conducted in the frequency range of 200 MHz-1 GHz. The test results indicate the measured antenna factors within +/- 1 dB of the nominal values supplied originally by the manufacturer.","PeriodicalId":104361,"journal":{"name":"Proceedings of the International Conference on Electromagnetic Interference and Compatibility","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A practical method for calibrating antennas\",\"authors\":\"B. Prakash, K. Suresh\",\"doi\":\"10.1109/ICEMIC.1999.871640\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Calibrated antennas are must for a certified EMC laboratory. A study has been conducted for calibrating antennas in the frequency range 200 MHz-1 GHz, which are needed for 1 meter radiated emission testing-RE02 of MIL-STD-461C. Measurements were conducted to ascertain the antenna factor for conical log spiral antenna by adapting 'Identical Two Antenna Method of calibration'. These measurements were conducted in the frequency range of 200 MHz-1 GHz. The test results indicate the measured antenna factors within +/- 1 dB of the nominal values supplied originally by the manufacturer.\",\"PeriodicalId\":104361,\"journal\":{\"name\":\"Proceedings of the International Conference on Electromagnetic Interference and Compatibility\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the International Conference on Electromagnetic Interference and Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEMIC.1999.871640\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the International Conference on Electromagnetic Interference and Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMIC.1999.871640","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Calibrated antennas are must for a certified EMC laboratory. A study has been conducted for calibrating antennas in the frequency range 200 MHz-1 GHz, which are needed for 1 meter radiated emission testing-RE02 of MIL-STD-461C. Measurements were conducted to ascertain the antenna factor for conical log spiral antenna by adapting 'Identical Two Antenna Method of calibration'. These measurements were conducted in the frequency range of 200 MHz-1 GHz. The test results indicate the measured antenna factors within +/- 1 dB of the nominal values supplied originally by the manufacturer.