H. Kitagawa, T. Maeda, S. Murata, T. Maki, T. Kaeriyama, A. Hyslop, A. Nishimura
{"title":"塑料包装应力导致TiW/Al-Si金属与硅化物接触失效","authors":"H. Kitagawa, T. Maeda, S. Murata, T. Maki, T. Kaeriyama, A. Hyslop, A. Nishimura","doi":"10.1109/RELPHY.1988.23429","DOIUrl":null,"url":null,"abstract":"The effects of long-term temperature/humidity stress on a TiW/Al-Si-TiSi/sub 2/ metal contact system were investigated. Plastic packaged DRAM test sites were subjected to conventional unbiased humidity testing procedures which induced electrical opens. Failure analysis showed these opens to occur in the contact region. The nature of this phenomenon was studied. It was found that plastic-package-induced shear stress causes plastic deformation of Al-Si and forces it into the contact hole. The mass built up inside the contact hole increases, causing an alloy formation, and can eventually lift the metal from the diffusion surface, causing the electrical open circuit to occur. One proposed solution is to enhance the protective overcoat's ability to absorb this stress and thus minimize its transmittal to the metallization system.<<ETX>>","PeriodicalId":102187,"journal":{"name":"26th Annual Proceedings Reliability Physics Symposium 1988","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Plastic packaging stress induced failures in TiW/Al-Si metal to silicide contacts\",\"authors\":\"H. Kitagawa, T. Maeda, S. Murata, T. Maki, T. Kaeriyama, A. Hyslop, A. Nishimura\",\"doi\":\"10.1109/RELPHY.1988.23429\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The effects of long-term temperature/humidity stress on a TiW/Al-Si-TiSi/sub 2/ metal contact system were investigated. Plastic packaged DRAM test sites were subjected to conventional unbiased humidity testing procedures which induced electrical opens. Failure analysis showed these opens to occur in the contact region. The nature of this phenomenon was studied. It was found that plastic-package-induced shear stress causes plastic deformation of Al-Si and forces it into the contact hole. The mass built up inside the contact hole increases, causing an alloy formation, and can eventually lift the metal from the diffusion surface, causing the electrical open circuit to occur. One proposed solution is to enhance the protective overcoat's ability to absorb this stress and thus minimize its transmittal to the metallization system.<<ETX>>\",\"PeriodicalId\":102187,\"journal\":{\"name\":\"26th Annual Proceedings Reliability Physics Symposium 1988\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-04-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"26th Annual Proceedings Reliability Physics Symposium 1988\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RELPHY.1988.23429\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"26th Annual Proceedings Reliability Physics Symposium 1988","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RELPHY.1988.23429","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Plastic packaging stress induced failures in TiW/Al-Si metal to silicide contacts
The effects of long-term temperature/humidity stress on a TiW/Al-Si-TiSi/sub 2/ metal contact system were investigated. Plastic packaged DRAM test sites were subjected to conventional unbiased humidity testing procedures which induced electrical opens. Failure analysis showed these opens to occur in the contact region. The nature of this phenomenon was studied. It was found that plastic-package-induced shear stress causes plastic deformation of Al-Si and forces it into the contact hole. The mass built up inside the contact hole increases, causing an alloy formation, and can eventually lift the metal from the diffusion surface, causing the electrical open circuit to occur. One proposed solution is to enhance the protective overcoat's ability to absorb this stress and thus minimize its transmittal to the metallization system.<>