多周期非局部方法对心脏图像序列进行去噪

John M. Batikian, M. Liebling
{"title":"多周期非局部方法对心脏图像序列进行去噪","authors":"John M. Batikian, M. Liebling","doi":"10.1109/ISBI.2014.6868059","DOIUrl":null,"url":null,"abstract":"Non-local means (NLM) noise reduction is effective yet computationally intensive, since each output pixel is a weighted average of all input pixels. Most implementations therefore restrict the scope of the average to a smaller neighborhood around each pixel, which limits the method's full potential. Here we propose to apply NLM to reduce the noise in fluorescence microscopy image sequences of the beating heart, whose quasi-repeatable pattern produces multiple realizations of similar image patches in different heart beats. We propose to restrict the averaging from the entire sequence to a subset of globally similar frames across multiple heart beats. Using a high-SNR brightfield microscopy image sequence of a beating embryonic zebrafish heart that we artificially corrupt with noise, we illustrate the benefits of selecting non-adjacent frames rather than the immediate temporal neighborhood in the vicinity of the pixel being denoised. The image quality of our NLM approach is also better than that obtained by directly computing the sample median of matching frames over multiple heartbeats, a commonly used method. Finally, we demonstrate the applicability of our proposed scheme to low-intensity fluorescence images of the embryonic zebrafish heart.","PeriodicalId":440405,"journal":{"name":"2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Multicycle non-local means denoising of cardiac image sequences\",\"authors\":\"John M. Batikian, M. Liebling\",\"doi\":\"10.1109/ISBI.2014.6868059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Non-local means (NLM) noise reduction is effective yet computationally intensive, since each output pixel is a weighted average of all input pixels. Most implementations therefore restrict the scope of the average to a smaller neighborhood around each pixel, which limits the method's full potential. Here we propose to apply NLM to reduce the noise in fluorescence microscopy image sequences of the beating heart, whose quasi-repeatable pattern produces multiple realizations of similar image patches in different heart beats. We propose to restrict the averaging from the entire sequence to a subset of globally similar frames across multiple heart beats. Using a high-SNR brightfield microscopy image sequence of a beating embryonic zebrafish heart that we artificially corrupt with noise, we illustrate the benefits of selecting non-adjacent frames rather than the immediate temporal neighborhood in the vicinity of the pixel being denoised. The image quality of our NLM approach is also better than that obtained by directly computing the sample median of matching frames over multiple heartbeats, a commonly used method. Finally, we demonstrate the applicability of our proposed scheme to low-intensity fluorescence images of the embryonic zebrafish heart.\",\"PeriodicalId\":440405,\"journal\":{\"name\":\"2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISBI.2014.6868059\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBI.2014.6868059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

非局部均值(NLM)降噪是有效的,但计算量很大,因为每个输出像素是所有输入像素的加权平均值。因此,大多数实现将平均值的范围限制在每个像素周围的较小邻域,这限制了该方法的全部潜力。在这里,我们提出应用NLM来降低心脏跳动的荧光显微镜图像序列中的噪声,其准可重复的模式在不同的心脏跳动中产生多次实现相似的图像斑块。我们建议将整个序列的平均限制为跨多个心跳的全局相似帧的子集。使用高信噪比的明场显微镜图像序列跳动的胚胎斑马鱼心脏,我们人为地用噪声腐蚀,我们说明了选择非相邻帧的好处,而不是在被去噪的像素附近的直接时间邻域。我们的NLM方法的图像质量也优于直接计算多个心跳匹配帧的样本中位数(一种常用的方法)。最后,我们证明了我们提出的方案适用于胚胎斑马鱼心脏的低强度荧光图像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Multicycle non-local means denoising of cardiac image sequences
Non-local means (NLM) noise reduction is effective yet computationally intensive, since each output pixel is a weighted average of all input pixels. Most implementations therefore restrict the scope of the average to a smaller neighborhood around each pixel, which limits the method's full potential. Here we propose to apply NLM to reduce the noise in fluorescence microscopy image sequences of the beating heart, whose quasi-repeatable pattern produces multiple realizations of similar image patches in different heart beats. We propose to restrict the averaging from the entire sequence to a subset of globally similar frames across multiple heart beats. Using a high-SNR brightfield microscopy image sequence of a beating embryonic zebrafish heart that we artificially corrupt with noise, we illustrate the benefits of selecting non-adjacent frames rather than the immediate temporal neighborhood in the vicinity of the pixel being denoised. The image quality of our NLM approach is also better than that obtained by directly computing the sample median of matching frames over multiple heartbeats, a commonly used method. Finally, we demonstrate the applicability of our proposed scheme to low-intensity fluorescence images of the embryonic zebrafish heart.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
MRI based attenuation correction for PET/MRI via MRF segmentation and sparse regression estimated CT DTI-DeformIt: Generating ground-truth validation data for diffusion tensor image analysis tasks Functional parcellation of the hippocampus by clustering resting state fMRI signals Detecting cell assembly interaction patterns via Bayesian based change-point detection and graph inference model Topological texture-based method for mass detection in breast ultrasound image
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1