{"title":"一种简单、新颖的恒开关频率三相逆变器变滞后带电流控制方法","authors":"Q. Yao, D. G. Holmes","doi":"10.1109/IAS.1993.299038","DOIUrl":null,"url":null,"abstract":"A novel method for implementing a variable hysteresis band current controller is described which achieves constant switching frequency without requiring a precise knowledge of the motor parameters. The controller works by using feedback and feedback variables to create a variable hysteresis band envelope, and then compensating for the interaction between phase back-EMFs that occurs when the neutral of a three-phase motor is left floating. The controller has good dynamic and steady-state response, and its performance is substantially immune to variations in the inverter DC supply voltage and motor parameters. It can be readily implemented in hardware, and only requires a few additional components compared to a conventional hysteresis current controller. Analytical, hardware implementation, simulation, FFT (fast Fourier transform) analysis, and experimental results are presented.<<ETX>>","PeriodicalId":345027,"journal":{"name":"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"181","resultStr":"{\"title\":\"A simple, novel method for variable-hysteresis-band current control of a three phase inverter with constant switching frequency\",\"authors\":\"Q. Yao, D. G. Holmes\",\"doi\":\"10.1109/IAS.1993.299038\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel method for implementing a variable hysteresis band current controller is described which achieves constant switching frequency without requiring a precise knowledge of the motor parameters. The controller works by using feedback and feedback variables to create a variable hysteresis band envelope, and then compensating for the interaction between phase back-EMFs that occurs when the neutral of a three-phase motor is left floating. The controller has good dynamic and steady-state response, and its performance is substantially immune to variations in the inverter DC supply voltage and motor parameters. It can be readily implemented in hardware, and only requires a few additional components compared to a conventional hysteresis current controller. Analytical, hardware implementation, simulation, FFT (fast Fourier transform) analysis, and experimental results are presented.<<ETX>>\",\"PeriodicalId\":345027,\"journal\":{\"name\":\"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"181\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1993.299038\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1993.299038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A simple, novel method for variable-hysteresis-band current control of a three phase inverter with constant switching frequency
A novel method for implementing a variable hysteresis band current controller is described which achieves constant switching frequency without requiring a precise knowledge of the motor parameters. The controller works by using feedback and feedback variables to create a variable hysteresis band envelope, and then compensating for the interaction between phase back-EMFs that occurs when the neutral of a three-phase motor is left floating. The controller has good dynamic and steady-state response, and its performance is substantially immune to variations in the inverter DC supply voltage and motor parameters. It can be readily implemented in hardware, and only requires a few additional components compared to a conventional hysteresis current controller. Analytical, hardware implementation, simulation, FFT (fast Fourier transform) analysis, and experimental results are presented.<>