E. Timurdogan, Sezin Nargul, H. Kavakli, E. Alaca, H. Urey
{"title":"磁致动MOEMS共振生物传感器阵列","authors":"E. Timurdogan, Sezin Nargul, H. Kavakli, E. Alaca, H. Urey","doi":"10.1109/OMEMS.2010.5672211","DOIUrl":null,"url":null,"abstract":"A biosensor platform is utilized in liquid for detection of His protein. T-shaped thin film nickel cantilevers are actuated magnetically using self-oscillation principle and the sensing is based on embedded diffraction gratings on the cantilevers with interferometric sensitivity. Experiments are performed in a custom 1ml liquid chamber and 5.7ng/ml detection sensitivity is demonstrated. Method is label-free, robust and allows multiplexing. It also doesn't require any electrical connections to the MEMS sensor chip. Therefore, it is suitable for real-time multi analyte screening using a disposable chip in a portable device.","PeriodicalId":421895,"journal":{"name":"2010 International Conference on Optical MEMS and Nanophotonics","volume":"127 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Magnetic actuated MOEMS resonant biosensor array\",\"authors\":\"E. Timurdogan, Sezin Nargul, H. Kavakli, E. Alaca, H. Urey\",\"doi\":\"10.1109/OMEMS.2010.5672211\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A biosensor platform is utilized in liquid for detection of His protein. T-shaped thin film nickel cantilevers are actuated magnetically using self-oscillation principle and the sensing is based on embedded diffraction gratings on the cantilevers with interferometric sensitivity. Experiments are performed in a custom 1ml liquid chamber and 5.7ng/ml detection sensitivity is demonstrated. Method is label-free, robust and allows multiplexing. It also doesn't require any electrical connections to the MEMS sensor chip. Therefore, it is suitable for real-time multi analyte screening using a disposable chip in a portable device.\",\"PeriodicalId\":421895,\"journal\":{\"name\":\"2010 International Conference on Optical MEMS and Nanophotonics\",\"volume\":\"127 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-12-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on Optical MEMS and Nanophotonics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/OMEMS.2010.5672211\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on Optical MEMS and Nanophotonics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OMEMS.2010.5672211","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A biosensor platform is utilized in liquid for detection of His protein. T-shaped thin film nickel cantilevers are actuated magnetically using self-oscillation principle and the sensing is based on embedded diffraction gratings on the cantilevers with interferometric sensitivity. Experiments are performed in a custom 1ml liquid chamber and 5.7ng/ml detection sensitivity is demonstrated. Method is label-free, robust and allows multiplexing. It also doesn't require any electrical connections to the MEMS sensor chip. Therefore, it is suitable for real-time multi analyte screening using a disposable chip in a portable device.