{"title":"基于最大似然估计框架的风力发电系统电网相互作用的电能质量改进","authors":"Farheen Chishti, Shadab Murshid, Bhim Singh","doi":"10.1109/PIICON49524.2020.9112971","DOIUrl":null,"url":null,"abstract":"The renewable energy intermittency indicating generation unavailability and volatility in a microgrid need to be addressed with prime attention. Here, in this work, the operational reliability and generation adequacy are reinforced by integrating a battery as the energy storage to the variable speed wind power generation system (WPGS). The grid interconnection to the system and combined performance offer significant benefits of improved power quality (PQ), energy sufficiency and surety by managing the local load support. The control of the battery allows the generation of the grid reference current. The grid side power converter utilizes the maximum-likelihood estimator based adaptive filter for improving the PQ indices by addressing the prevailing concerns stemmed by nonlinear loads. The control has high tracking performance while dealing with the contingency event of load variation. The machine side power converter utilizes vector control for obtaining the switching pulses. A hardware prototype is developed and the test results acquired substantiate that the work carried out is effective, reliable and offer improved PQ indices.","PeriodicalId":422853,"journal":{"name":"2020 IEEE 9th Power India International Conference (PIICON)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Grid Interaction of Wind Power Generation System Using Maximum-Likelihood Estimator Framework for Power Quality Improvement\",\"authors\":\"Farheen Chishti, Shadab Murshid, Bhim Singh\",\"doi\":\"10.1109/PIICON49524.2020.9112971\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The renewable energy intermittency indicating generation unavailability and volatility in a microgrid need to be addressed with prime attention. Here, in this work, the operational reliability and generation adequacy are reinforced by integrating a battery as the energy storage to the variable speed wind power generation system (WPGS). The grid interconnection to the system and combined performance offer significant benefits of improved power quality (PQ), energy sufficiency and surety by managing the local load support. The control of the battery allows the generation of the grid reference current. The grid side power converter utilizes the maximum-likelihood estimator based adaptive filter for improving the PQ indices by addressing the prevailing concerns stemmed by nonlinear loads. The control has high tracking performance while dealing with the contingency event of load variation. The machine side power converter utilizes vector control for obtaining the switching pulses. A hardware prototype is developed and the test results acquired substantiate that the work carried out is effective, reliable and offer improved PQ indices.\",\"PeriodicalId\":422853,\"journal\":{\"name\":\"2020 IEEE 9th Power India International Conference (PIICON)\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 9th Power India International Conference (PIICON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PIICON49524.2020.9112971\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 9th Power India International Conference (PIICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PIICON49524.2020.9112971","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

微电网中可再生能源的间歇性表明发电不可用和波动性需要得到高度重视。在此,在本工作中,通过将电池作为储能集成到变速风力发电系统(WPGS)中,增强了运行可靠性和发电充分性。系统的电网互联和综合性能通过管理本地负载支持提供了改善电能质量(PQ),能源充足性和安全性的显着优势。电池的控制允许产生电网参考电流。电网侧功率变换器利用基于极大似然估计的自适应滤波器来改善PQ指标,解决了非线性负荷引起的普遍关注。该控制在处理负荷变化的偶然性事件时具有良好的跟踪性能。机器侧功率变换器利用矢量控制来获取开关脉冲。开发了硬件样机,测试结果表明所做的工作是有效、可靠的,并提供了改进的PQ指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Grid Interaction of Wind Power Generation System Using Maximum-Likelihood Estimator Framework for Power Quality Improvement
The renewable energy intermittency indicating generation unavailability and volatility in a microgrid need to be addressed with prime attention. Here, in this work, the operational reliability and generation adequacy are reinforced by integrating a battery as the energy storage to the variable speed wind power generation system (WPGS). The grid interconnection to the system and combined performance offer significant benefits of improved power quality (PQ), energy sufficiency and surety by managing the local load support. The control of the battery allows the generation of the grid reference current. The grid side power converter utilizes the maximum-likelihood estimator based adaptive filter for improving the PQ indices by addressing the prevailing concerns stemmed by nonlinear loads. The control has high tracking performance while dealing with the contingency event of load variation. The machine side power converter utilizes vector control for obtaining the switching pulses. A hardware prototype is developed and the test results acquired substantiate that the work carried out is effective, reliable and offer improved PQ indices.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An Improved Grid Synchronization Method of Grid-Interactive Power Converter System During Distorted Grid Conditions Design and Implementation of Biquad Filter for Shunt Compensation under Normal and Distorted Grid Conditions High Voltage Gain DC-DC Non-Isolated Converter with Generalized Stages Irregular-shaped Particle Motion and Charge Transfer Mechanism in Transformer Oil under Varying Field Reduce, Recycle And Reuse First Ever Initiative By Any Haryana Govt. Power Utility And Its Outcomes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1