Giljun Ahn, Junmin Lee, C. Park, Myeongbaek Youn, B. Youn
{"title":"基于参考电压的永磁同步电动机匝间短路故障检测","authors":"Giljun Ahn, Junmin Lee, C. Park, Myeongbaek Youn, B. Youn","doi":"10.1109/DEMPED.2019.8864924","DOIUrl":null,"url":null,"abstract":"This paper proposes a method for detecting inter-turn short circuit faults of surface-mounted permanent magnet synchronous motors (SPMSMs) based on reference voltage. The proposed method consists of three steps. First, from the mathematical model of faulty PMSM, a reference voltage vector in the dq-frame is separated into a healthy voltage and a faulty voltage. Second, the faulty voltage is further decomposed into a DC component and a 2nd harmonic component. Third, the relationship between these components and the inter-turn fault severity is identified. Based on the relationship, this paper proposes two fault indicators; DC bias and 2nd harmonic amplitude. Simulation results verify the effectiveness of the proposed method. The proposed method can detect inter-turn short circuit faults under low sampling rate and without the need for additional sensors. This strength can facilitate on-line fault detection.","PeriodicalId":397001,"journal":{"name":"2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Inter-turn Short Circuit Fault Detection in Permanent Magnet Synchronous Motors Based on Reference Voltage\",\"authors\":\"Giljun Ahn, Junmin Lee, C. Park, Myeongbaek Youn, B. Youn\",\"doi\":\"10.1109/DEMPED.2019.8864924\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a method for detecting inter-turn short circuit faults of surface-mounted permanent magnet synchronous motors (SPMSMs) based on reference voltage. The proposed method consists of three steps. First, from the mathematical model of faulty PMSM, a reference voltage vector in the dq-frame is separated into a healthy voltage and a faulty voltage. Second, the faulty voltage is further decomposed into a DC component and a 2nd harmonic component. Third, the relationship between these components and the inter-turn fault severity is identified. Based on the relationship, this paper proposes two fault indicators; DC bias and 2nd harmonic amplitude. Simulation results verify the effectiveness of the proposed method. The proposed method can detect inter-turn short circuit faults under low sampling rate and without the need for additional sensors. This strength can facilitate on-line fault detection.\",\"PeriodicalId\":397001,\"journal\":{\"name\":\"2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)\",\"volume\":\"30 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DEMPED.2019.8864924\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEMPED.2019.8864924","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Inter-turn Short Circuit Fault Detection in Permanent Magnet Synchronous Motors Based on Reference Voltage
This paper proposes a method for detecting inter-turn short circuit faults of surface-mounted permanent magnet synchronous motors (SPMSMs) based on reference voltage. The proposed method consists of three steps. First, from the mathematical model of faulty PMSM, a reference voltage vector in the dq-frame is separated into a healthy voltage and a faulty voltage. Second, the faulty voltage is further decomposed into a DC component and a 2nd harmonic component. Third, the relationship between these components and the inter-turn fault severity is identified. Based on the relationship, this paper proposes two fault indicators; DC bias and 2nd harmonic amplitude. Simulation results verify the effectiveness of the proposed method. The proposed method can detect inter-turn short circuit faults under low sampling rate and without the need for additional sensors. This strength can facilitate on-line fault detection.