{"title":"Microflex:微系统混合集成的新技术","authors":"H. Beutel, T. Stieglitz, J. Meyer","doi":"10.1109/MEMSYS.1998.659773","DOIUrl":null,"url":null,"abstract":"This paper describes a new interconnection wire method which allows versatile multiple strand connections between microsensors: sensor arrays and integrated circuits (IC). The interconnection method is termed Micro Flex Interconnects (MFI). One example for this technology is the connection of implantable, highly flexible neural micro devices to electronics for interfacing to the external world. The interconnection technique is based on a novel multilayer process using polyimide (Du Pont PI 2611). The thickness of the polyimide structure ranges from 5 to 15 /spl mu/m including the insulation layers. Several metallization layers can be embedded in the material. This approach exhibits same advantages. The involved material is non-toxic and the ICs do not need any additional bond pad metallization. The MFI technique has been proven long-term stable. The metallization material can be chosen accordingly for electrodes, conducting lines, and connection pads. An commercial ball wedge bonder is the only equipment needed to perform the MFI method.","PeriodicalId":340972,"journal":{"name":"Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176","volume":"97 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Microflex: a new technique for hybrid integration for microsystems\",\"authors\":\"H. Beutel, T. Stieglitz, J. Meyer\",\"doi\":\"10.1109/MEMSYS.1998.659773\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes a new interconnection wire method which allows versatile multiple strand connections between microsensors: sensor arrays and integrated circuits (IC). The interconnection method is termed Micro Flex Interconnects (MFI). One example for this technology is the connection of implantable, highly flexible neural micro devices to electronics for interfacing to the external world. The interconnection technique is based on a novel multilayer process using polyimide (Du Pont PI 2611). The thickness of the polyimide structure ranges from 5 to 15 /spl mu/m including the insulation layers. Several metallization layers can be embedded in the material. This approach exhibits same advantages. The involved material is non-toxic and the ICs do not need any additional bond pad metallization. The MFI technique has been proven long-term stable. The metallization material can be chosen accordingly for electrodes, conducting lines, and connection pads. An commercial ball wedge bonder is the only equipment needed to perform the MFI method.\",\"PeriodicalId\":340972,\"journal\":{\"name\":\"Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176\",\"volume\":\"97 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-01-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MEMSYS.1998.659773\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMSYS.1998.659773","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Microflex: a new technique for hybrid integration for microsystems
This paper describes a new interconnection wire method which allows versatile multiple strand connections between microsensors: sensor arrays and integrated circuits (IC). The interconnection method is termed Micro Flex Interconnects (MFI). One example for this technology is the connection of implantable, highly flexible neural micro devices to electronics for interfacing to the external world. The interconnection technique is based on a novel multilayer process using polyimide (Du Pont PI 2611). The thickness of the polyimide structure ranges from 5 to 15 /spl mu/m including the insulation layers. Several metallization layers can be embedded in the material. This approach exhibits same advantages. The involved material is non-toxic and the ICs do not need any additional bond pad metallization. The MFI technique has been proven long-term stable. The metallization material can be chosen accordingly for electrodes, conducting lines, and connection pads. An commercial ball wedge bonder is the only equipment needed to perform the MFI method.