新老聚乙烯绝缘电缆击穿部位的检验

R. Naybour
{"title":"新老聚乙烯绝缘电缆击穿部位的检验","authors":"R. Naybour","doi":"10.1109/ICSD.1989.69162","DOIUrl":null,"url":null,"abstract":"Discharges have been monitored and located in short lengths of cable tested to breakdown. These tests have been used to detect prebreakdown deterioration. The discharge location system is novel and has enabled limited energy breakdown sites to be located. Not all the breakdowns were initiated at the region of the inner screen boundary. In short-term tests to breakdown on new and dry aged cables at a maximum field of 30 MV/m there was no gradual increase in the discharge level above the detection limit of 1 pC. It appears possible that ageing with applied voltage at ambient temperature can improve the breakdown strength.<<ETX>>","PeriodicalId":184126,"journal":{"name":"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics","volume":"237 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Examination of the breakdown site in new and aged polyethylene insulated cables\",\"authors\":\"R. Naybour\",\"doi\":\"10.1109/ICSD.1989.69162\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Discharges have been monitored and located in short lengths of cable tested to breakdown. These tests have been used to detect prebreakdown deterioration. The discharge location system is novel and has enabled limited energy breakdown sites to be located. Not all the breakdowns were initiated at the region of the inner screen boundary. In short-term tests to breakdown on new and dry aged cables at a maximum field of 30 MV/m there was no gradual increase in the discharge level above the detection limit of 1 pC. It appears possible that ageing with applied voltage at ambient temperature can improve the breakdown strength.<<ETX>>\",\"PeriodicalId\":184126,\"journal\":{\"name\":\"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics\",\"volume\":\"237 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSD.1989.69162\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSD.1989.69162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

对放电进行了监测,并在测试击穿的短电缆中进行了定位。这些试验已用于检测预击穿劣化。放电定位系统是新颖的,能够定位有限能量击穿点。并非所有的故障都是在屏幕内部边界区域开始的。在最大电场为30 MV/m的情况下,对新电缆和干老化电缆进行的短期击穿试验中,放电水平在1 pC检测限以上没有逐渐增加。在环境温度下施加电压老化似乎可以提高击穿强度
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Examination of the breakdown site in new and aged polyethylene insulated cables
Discharges have been monitored and located in short lengths of cable tested to breakdown. These tests have been used to detect prebreakdown deterioration. The discharge location system is novel and has enabled limited energy breakdown sites to be located. Not all the breakdowns were initiated at the region of the inner screen boundary. In short-term tests to breakdown on new and dry aged cables at a maximum field of 30 MV/m there was no gradual increase in the discharge level above the detection limit of 1 pC. It appears possible that ageing with applied voltage at ambient temperature can improve the breakdown strength.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
On the mechanism of partial discharges in gaseous cavities in contact with solid or liquid insulators The initiation and growth of AC tree in polyethylene Effects of the field dependent occupation of electrical-stress-generated traps on the conduction and breakdown of thin SiO/sub 2/ films A model of the electrical breakdown process due to electrical treeing growth Dielectric breakdown and partial discharge in BaTiO/sub 3/ ceramics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1