用定向过欠压协调继电器保护微电网

N. Patil, M. Kirar, P. Paliwal, S. K. Wankhede
{"title":"用定向过欠压协调继电器保护微电网","authors":"N. Patil, M. Kirar, P. Paliwal, S. K. Wankhede","doi":"10.1109/SeFet48154.2021.9375695","DOIUrl":null,"url":null,"abstract":"The power system protection is the most vital concern to be addressed with the proliferation of DG. Integration of DG changes the direction of power flow and level of fault current that makes protection of microgrid very challenging. DG integrated through power electronics (PE) converters can decrease or increase fault current level, based upon the location of DG. Due to this existing protection schemes may not work properly or fails to operate. Thus, the selection and design of proper protection scheme is very important for maintaining system reliability. The presented work is based upon the various microgrid protection issues and to implement a suitable protection scheme which works in both grids connected and islanded mode. A novel technique is proposed to design and analysis undervoltage and directional overcurrent relays protection with suitable settings for the microgrid system. Proper relay coordination for protection of microgrid in both islanding and grid connected modes of operation is shown. Simulation studies is carried out on ETAP software.","PeriodicalId":232560,"journal":{"name":"2021 International Conference on Sustainable Energy and Future Electric Transportation (SEFET)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Protection of Microgrid Using Coordinated Directional Overcurrent and Undervoltage Relay\",\"authors\":\"N. Patil, M. Kirar, P. Paliwal, S. K. Wankhede\",\"doi\":\"10.1109/SeFet48154.2021.9375695\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The power system protection is the most vital concern to be addressed with the proliferation of DG. Integration of DG changes the direction of power flow and level of fault current that makes protection of microgrid very challenging. DG integrated through power electronics (PE) converters can decrease or increase fault current level, based upon the location of DG. Due to this existing protection schemes may not work properly or fails to operate. Thus, the selection and design of proper protection scheme is very important for maintaining system reliability. The presented work is based upon the various microgrid protection issues and to implement a suitable protection scheme which works in both grids connected and islanded mode. A novel technique is proposed to design and analysis undervoltage and directional overcurrent relays protection with suitable settings for the microgrid system. Proper relay coordination for protection of microgrid in both islanding and grid connected modes of operation is shown. Simulation studies is carried out on ETAP software.\",\"PeriodicalId\":232560,\"journal\":{\"name\":\"2021 International Conference on Sustainable Energy and Future Electric Transportation (SEFET)\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Sustainable Energy and Future Electric Transportation (SEFET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SeFet48154.2021.9375695\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Sustainable Energy and Future Electric Transportation (SEFET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SeFet48154.2021.9375695","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

随着分布式发电的扩散,电力系统的保护是人们最关心的问题。DG的集成改变了潮流方向和故障电流水平,使微电网的保护变得非常具有挑战性。通过电力电子(PE)转换器集成的DG可以根据DG的位置降低或增加故障电流水平。因此,现有的保护方案可能无法正常工作或无法运行。因此,选择和设计合适的保护方案对保持系统的可靠性至关重要。提出的工作是基于各种微电网保护问题,并实现一个合适的保护方案,在电网连接和孤岛模式下工作。提出了一种设计和分析微电网欠压和定向过流继电保护的新方法。给出了孤岛和并网两种运行方式下微电网保护的继电协调方法。在ETAP软件上进行了仿真研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Protection of Microgrid Using Coordinated Directional Overcurrent and Undervoltage Relay
The power system protection is the most vital concern to be addressed with the proliferation of DG. Integration of DG changes the direction of power flow and level of fault current that makes protection of microgrid very challenging. DG integrated through power electronics (PE) converters can decrease or increase fault current level, based upon the location of DG. Due to this existing protection schemes may not work properly or fails to operate. Thus, the selection and design of proper protection scheme is very important for maintaining system reliability. The presented work is based upon the various microgrid protection issues and to implement a suitable protection scheme which works in both grids connected and islanded mode. A novel technique is proposed to design and analysis undervoltage and directional overcurrent relays protection with suitable settings for the microgrid system. Proper relay coordination for protection of microgrid in both islanding and grid connected modes of operation is shown. Simulation studies is carried out on ETAP software.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Retrofication Of ICE Driven Auto-Rickshaw Seamless Transition between Grid-Connected and Islanded Operation Modes for Hybrid PV-BESS Combination used in Single-Phase, Critical Load Applications A Critical Study on Campus Energy Monitoring System and Role of IoT A Novel Switched-Capacitor Based Three-phase MultiLevel Inverter Fed induction motor for Agricultural Applications A New Single-Phase Five-Level Neutral Point Clamped Cascaded Multilevel Inverter for Minimization of Leakage Current in PV Systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1