数字控制DC-DC变换器的自适应软启动特性

F. Kurokawa, S. Sagara, J. Takano
{"title":"数字控制DC-DC变换器的自适应软启动特性","authors":"F. Kurokawa, S. Sagara, J. Takano","doi":"10.1109/VPPC.2012.6422648","DOIUrl":null,"url":null,"abstract":"This paper presents adaptive soft-start characteristics of digital control dc-dc converter. For the soft-start operation, it is important to detect the load resistor. In conventional analog method, the fixed large parameter of the soft-start circuit must be set by the condition. In the proposed digital control, the load resistor can be calculated with the output voltage and output current, and the optimal time constant of the soft-start circuit can be decided by detecting load dynamically in voltage mode. Therefore, it doesn't need to set large value for the time constant. In the current mode control, the optimal upper limit can be decided by load resistor. It is confirmed that the digital control methods have superior soft-start characteristics compared to the analog one.","PeriodicalId":341659,"journal":{"name":"2012 IEEE Vehicle Power and Propulsion Conference","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Adaptive soft-start characteristics of digital control DC-DC converter\",\"authors\":\"F. Kurokawa, S. Sagara, J. Takano\",\"doi\":\"10.1109/VPPC.2012.6422648\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents adaptive soft-start characteristics of digital control dc-dc converter. For the soft-start operation, it is important to detect the load resistor. In conventional analog method, the fixed large parameter of the soft-start circuit must be set by the condition. In the proposed digital control, the load resistor can be calculated with the output voltage and output current, and the optimal time constant of the soft-start circuit can be decided by detecting load dynamically in voltage mode. Therefore, it doesn't need to set large value for the time constant. In the current mode control, the optimal upper limit can be decided by load resistor. It is confirmed that the digital control methods have superior soft-start characteristics compared to the analog one.\",\"PeriodicalId\":341659,\"journal\":{\"name\":\"2012 IEEE Vehicle Power and Propulsion Conference\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Vehicle Power and Propulsion Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/VPPC.2012.6422648\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Vehicle Power and Propulsion Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VPPC.2012.6422648","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了数字控制dc-dc变换器的自适应软启动特性。对于软启动操作,检测负载电阻是很重要的。在传统的模拟方法中,软启动电路的固定大参数必须由条件设定。在本文提出的数字控制中,可以根据输出电压和输出电流计算负载电阻,并通过在电压模式下动态检测负载来确定软启动电路的最佳时间常数。因此,不需要为时间常数设置较大的值。在电流模式控制中,最优上限可由负载电阻决定。结果表明,与模拟控制相比,数字控制方法具有更好的软启动特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Adaptive soft-start characteristics of digital control DC-DC converter
This paper presents adaptive soft-start characteristics of digital control dc-dc converter. For the soft-start operation, it is important to detect the load resistor. In conventional analog method, the fixed large parameter of the soft-start circuit must be set by the condition. In the proposed digital control, the load resistor can be calculated with the output voltage and output current, and the optimal time constant of the soft-start circuit can be decided by detecting load dynamically in voltage mode. Therefore, it doesn't need to set large value for the time constant. In the current mode control, the optimal upper limit can be decided by load resistor. It is confirmed that the digital control methods have superior soft-start characteristics compared to the analog one.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Datasheet-based modeling of Li-Ion batteries The proposal of wheel slip control method with peak point search and the test result Battery duty profile of a heavy-duty trolleybus The evaluation of WAVE communication for seamless services under V2I environment Energetic Macroscopic Representation and inversion-based control of the traction system of a hybrid locomotive
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1