系统参数对可再生电站谐波畸变贡献的影响

Francois du Plessis, J. Beukes
{"title":"系统参数对可再生电站谐波畸变贡献的影响","authors":"Francois du Plessis, J. Beukes","doi":"10.1109/ICHQP53011.2022.9808780","DOIUrl":null,"url":null,"abstract":"Harmonic analysis of inverters in renewable power plants can be very complex and is often only based on measurement data. This paper uses the harmonic modelling technique specified by IEC 61400-21-3 to perform a harmonic analysis on a specific inverter system and analyse the effect of grid impedance and control system parameters on harmonic distortion. Harmonic grid current distortion is often used for compliance of renewable power plants. Through impedance based arguments based on the harmonic model, this paper shows how harmonic currents, produced by the interaction between background voltage distortion and the system impedance, can decrease harmonic voltage distortion at the point of connection of a renewable power plant.","PeriodicalId":249133,"journal":{"name":"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of System Parameters on Harmonic Distortion Contributions of Renewable Power Plants\",\"authors\":\"Francois du Plessis, J. Beukes\",\"doi\":\"10.1109/ICHQP53011.2022.9808780\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Harmonic analysis of inverters in renewable power plants can be very complex and is often only based on measurement data. This paper uses the harmonic modelling technique specified by IEC 61400-21-3 to perform a harmonic analysis on a specific inverter system and analyse the effect of grid impedance and control system parameters on harmonic distortion. Harmonic grid current distortion is often used for compliance of renewable power plants. Through impedance based arguments based on the harmonic model, this paper shows how harmonic currents, produced by the interaction between background voltage distortion and the system impedance, can decrease harmonic voltage distortion at the point of connection of a renewable power plant.\",\"PeriodicalId\":249133,\"journal\":{\"name\":\"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)\",\"volume\":\"43 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP53011.2022.9808780\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP53011.2022.9808780","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

可再生能源发电厂逆变器的谐波分析非常复杂,通常仅基于测量数据。本文采用IEC 61400-21-3规定的谐波建模技术,对特定逆变系统进行谐波分析,分析电网阻抗和控制系统参数对谐波畸变的影响。谐波电网电流畸变常用于可再生能源发电厂的合规性。本文通过基于谐波模型的阻抗论证,说明了背景电压畸变与系统阻抗相互作用产生的谐波电流如何降低可再生电站接入点的谐波电压畸变。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of System Parameters on Harmonic Distortion Contributions of Renewable Power Plants
Harmonic analysis of inverters in renewable power plants can be very complex and is often only based on measurement data. This paper uses the harmonic modelling technique specified by IEC 61400-21-3 to perform a harmonic analysis on a specific inverter system and analyse the effect of grid impedance and control system parameters on harmonic distortion. Harmonic grid current distortion is often used for compliance of renewable power plants. Through impedance based arguments based on the harmonic model, this paper shows how harmonic currents, produced by the interaction between background voltage distortion and the system impedance, can decrease harmonic voltage distortion at the point of connection of a renewable power plant.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Voltage-Current Ratio Difference Method: Recommended for IEEE Standard 1547 to Determine the Customer Harmonic Contribution Operation of a Distributed Generation Plant in a Power Supply System with Non-linear and Asymmetric Load Trend analysis for power quality parameters based on long-term measurement campaigns Power Quality Data Platform for Analysis and Location of Voltage Dips: a Preliminary Study Classification of Scalogram Signatures for Power Quality Disturbances Using Transfer Learning
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1