{"title":"经皮遥测链路中光学接收器的设计优化","authors":"Tianyi Liu, J. Anders, M. Ortmanns","doi":"10.1109/BIOCAS.2013.6679710","DOIUrl":null,"url":null,"abstract":"This paper presents a design methodology for an optimization of the optical receiver in a neural recording system. In the transcutaneous optical telemetric link (TOTL) system, light/tissue interaction produces significant scattering of the transmitted photons. Therefore, in order to increase the transmission efficiency, it is in principle advantageous to use a photodiode with a larger size to collect more scattered photons. The photodiode size, however, is limited by the bandwidth requirement. In this paper, we derive a mathematical expression of the maximum photodiode size in the presence of constraints imposed by its bias voltage and the receiver bandwidth. A numerical example using real-world TOTL system parameters is given to demonstrate the design methodology. The trade off between transmission efficiency, noise and inter-symbol interference (ISI) in terms of the 3-dB bandwidth of the receiver is investigated. To this end, receivers with bandwidth about 4/3, 3/3, 2/3 and 1/3 of the data rate are compared with respect to the sensitivity. It was found that the receiver bandwidth of 2/3 of the data rate achieves the highest sensitivity for thin tissue (2 mm) and that a receiver bandwidth of 1/3 of the data rate is preferable for thicker tissues (5 and 8 mm).","PeriodicalId":344317,"journal":{"name":"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)","volume":"47 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Design optimization of the optical receiver in transcutaneous telemetric links\",\"authors\":\"Tianyi Liu, J. Anders, M. Ortmanns\",\"doi\":\"10.1109/BIOCAS.2013.6679710\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a design methodology for an optimization of the optical receiver in a neural recording system. In the transcutaneous optical telemetric link (TOTL) system, light/tissue interaction produces significant scattering of the transmitted photons. Therefore, in order to increase the transmission efficiency, it is in principle advantageous to use a photodiode with a larger size to collect more scattered photons. The photodiode size, however, is limited by the bandwidth requirement. In this paper, we derive a mathematical expression of the maximum photodiode size in the presence of constraints imposed by its bias voltage and the receiver bandwidth. A numerical example using real-world TOTL system parameters is given to demonstrate the design methodology. The trade off between transmission efficiency, noise and inter-symbol interference (ISI) in terms of the 3-dB bandwidth of the receiver is investigated. To this end, receivers with bandwidth about 4/3, 3/3, 2/3 and 1/3 of the data rate are compared with respect to the sensitivity. It was found that the receiver bandwidth of 2/3 of the data rate achieves the highest sensitivity for thin tissue (2 mm) and that a receiver bandwidth of 1/3 of the data rate is preferable for thicker tissues (5 and 8 mm).\",\"PeriodicalId\":344317,\"journal\":{\"name\":\"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"volume\":\"47 5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOCAS.2013.6679710\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2013.6679710","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design optimization of the optical receiver in transcutaneous telemetric links
This paper presents a design methodology for an optimization of the optical receiver in a neural recording system. In the transcutaneous optical telemetric link (TOTL) system, light/tissue interaction produces significant scattering of the transmitted photons. Therefore, in order to increase the transmission efficiency, it is in principle advantageous to use a photodiode with a larger size to collect more scattered photons. The photodiode size, however, is limited by the bandwidth requirement. In this paper, we derive a mathematical expression of the maximum photodiode size in the presence of constraints imposed by its bias voltage and the receiver bandwidth. A numerical example using real-world TOTL system parameters is given to demonstrate the design methodology. The trade off between transmission efficiency, noise and inter-symbol interference (ISI) in terms of the 3-dB bandwidth of the receiver is investigated. To this end, receivers with bandwidth about 4/3, 3/3, 2/3 and 1/3 of the data rate are compared with respect to the sensitivity. It was found that the receiver bandwidth of 2/3 of the data rate achieves the highest sensitivity for thin tissue (2 mm) and that a receiver bandwidth of 1/3 of the data rate is preferable for thicker tissues (5 and 8 mm).