考虑最小可调度发电运行成本的最优可再生能源集成

Veeraya Imcharoenkul, S. Chaitusaney
{"title":"考虑最小可调度发电运行成本的最优可再生能源集成","authors":"Veeraya Imcharoenkul, S. Chaitusaney","doi":"10.1109/ecti-con49241.2020.9158289","DOIUrl":null,"url":null,"abstract":"This paper proposes a method to determine the optimal renewable energy (RE) integration in the electrical system considering the minimization of dispatchable generation operating costs. The RE generation consists of solar and wind generation while the conventional generation, which is considered as the dispatchable generation, consists of natural gas combined-cycle and coal thermal generation. In the analysis, a unit commitment is executed based on the operating costs, i.e. variable costs and load following costs of the dispatchable generation. Moreover, the proposed method is aimed to accommodate the electricity demand with the consideration of generation characteristics such as minimum generation, ramp rate, minimum uptime and minimum downtime. The result shows that the optimal renewable energy integration is at 40% of the total electricity demand. Beyond the optimal level, the dispatchable generation operating costs tend to be higher because of the RE compensation operation.","PeriodicalId":371552,"journal":{"name":"2020 17th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Optimal Renewable Energy Integration Considering Minimum Dispatchable Generation Operating Costs\",\"authors\":\"Veeraya Imcharoenkul, S. Chaitusaney\",\"doi\":\"10.1109/ecti-con49241.2020.9158289\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a method to determine the optimal renewable energy (RE) integration in the electrical system considering the minimization of dispatchable generation operating costs. The RE generation consists of solar and wind generation while the conventional generation, which is considered as the dispatchable generation, consists of natural gas combined-cycle and coal thermal generation. In the analysis, a unit commitment is executed based on the operating costs, i.e. variable costs and load following costs of the dispatchable generation. Moreover, the proposed method is aimed to accommodate the electricity demand with the consideration of generation characteristics such as minimum generation, ramp rate, minimum uptime and minimum downtime. The result shows that the optimal renewable energy integration is at 40% of the total electricity demand. Beyond the optimal level, the dispatchable generation operating costs tend to be higher because of the RE compensation operation.\",\"PeriodicalId\":371552,\"journal\":{\"name\":\"2020 17th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 17th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ecti-con49241.2020.9158289\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 17th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ecti-con49241.2020.9158289","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种考虑可调度发电运行成本最小化的电力系统可再生能源最优集成方案。可再生能源发电由太阳能发电和风能发电组成,而常规发电由天然气联合循环发电和煤电联产组成,被认为是可调度发电。在分析中,基于运行成本执行单元承诺,即可调度发电的可变成本和负载跟随成本。此外,所提出的方法旨在通过考虑发电特性(如最小发电量、斜坡率、最小正常运行时间和最小停机时间)来适应电力需求。结果表明,最优的可再生能源并网比例为总电力需求的40%。在最优水平之外,可调度发电运行成本由于可再生能源的补偿运行而趋于升高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimal Renewable Energy Integration Considering Minimum Dispatchable Generation Operating Costs
This paper proposes a method to determine the optimal renewable energy (RE) integration in the electrical system considering the minimization of dispatchable generation operating costs. The RE generation consists of solar and wind generation while the conventional generation, which is considered as the dispatchable generation, consists of natural gas combined-cycle and coal thermal generation. In the analysis, a unit commitment is executed based on the operating costs, i.e. variable costs and load following costs of the dispatchable generation. Moreover, the proposed method is aimed to accommodate the electricity demand with the consideration of generation characteristics such as minimum generation, ramp rate, minimum uptime and minimum downtime. The result shows that the optimal renewable energy integration is at 40% of the total electricity demand. Beyond the optimal level, the dispatchable generation operating costs tend to be higher because of the RE compensation operation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Simple Tunable Biquadratic Digital Bandpass Filter Design for Spectrum Sensing in Cognitive Radio ElectricVehicle Simulator Using DC Drives Comparison of Machine Learning Algorithm’s on Self-Driving Car Navigation using Nvidia Jetson Nano Enhancing CNN Based Knowledge Graph Embedding Algorithms Using Auxiliary Vectors: A Case Study of Wordnet Knowledge Graph A Study of Radiated EMI Predictions from Measured Common-mode Currents for Switching Power Supplies
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1