Belle-II型顶点探测器s-CVD辐射监测与束流中止系统

L. Bosisio, C. Licata, L. Lanceri, L. Vitale
{"title":"Belle-II型顶点探测器s-CVD辐射监测与束流中止系统","authors":"L. Bosisio, C. Licata, L. Lanceri, L. Vitale","doi":"10.1109/NSSMIC.2016.8069890","DOIUrl":null,"url":null,"abstract":"The Belle-II VerteX Detector (VXD) is a 6 layers silicon tracker device that will cope with an unprecedented luminosity of 8 × 10<sup>35</sup> cm<sup>−2</sup> s<sup>−1</sup> achievable by the new SuperKEKB e<sup>+</sup>e<sup>−</sup> collider, now under commissioning at the KEK laboratory (Tsukuba, Japan). A radiation monitoring and beam abort system has been developed based on single-crystal s-CVD diamond sensors. The sensors will be placed in 20 key positions in the vicinity of the interaction region. The severe space limitations require a remote readout of the sensors. In this contribution we present the system design, along with the sensor characterisation procedure. We present also the preliminary results with the prototype system during the first SuperKEKB commissioning phase in February-June 2016.","PeriodicalId":184587,"journal":{"name":"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)","volume":"94 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The s-CVD radiation monitoring and beam abort system of the Belle-II vertex detector\",\"authors\":\"L. Bosisio, C. Licata, L. Lanceri, L. Vitale\",\"doi\":\"10.1109/NSSMIC.2016.8069890\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Belle-II VerteX Detector (VXD) is a 6 layers silicon tracker device that will cope with an unprecedented luminosity of 8 × 10<sup>35</sup> cm<sup>−2</sup> s<sup>−1</sup> achievable by the new SuperKEKB e<sup>+</sup>e<sup>−</sup> collider, now under commissioning at the KEK laboratory (Tsukuba, Japan). A radiation monitoring and beam abort system has been developed based on single-crystal s-CVD diamond sensors. The sensors will be placed in 20 key positions in the vicinity of the interaction region. The severe space limitations require a remote readout of the sensors. In this contribution we present the system design, along with the sensor characterisation procedure. We present also the preliminary results with the prototype system during the first SuperKEKB commissioning phase in February-June 2016.\",\"PeriodicalId\":184587,\"journal\":{\"name\":\"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)\",\"volume\":\"94 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2016.8069890\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2016.8069890","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

Belle-II顶点探测器(VXD)是一种6层硅跟踪装置,将处理由新的SuperKEKB e+e -对撞机实现的前所未有的8 × 1035 cm−2 s−1的亮度,该对撞机目前正在KEK实验室(日本Tsukuba)进行调试。研制了一种基于单晶s-CVD金刚石传感器的辐射监测和束流中止系统。传感器将被放置在交互区域附近的20个关键位置。严重的空间限制需要远程读出传感器。在这个贡献中,我们提出了系统设计,以及传感器表征程序。在2016年2月至6月的第一个SuperKEKB调试阶段,我们还展示了原型系统的初步结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The s-CVD radiation monitoring and beam abort system of the Belle-II vertex detector
The Belle-II VerteX Detector (VXD) is a 6 layers silicon tracker device that will cope with an unprecedented luminosity of 8 × 1035 cm−2 s−1 achievable by the new SuperKEKB e+e collider, now under commissioning at the KEK laboratory (Tsukuba, Japan). A radiation monitoring and beam abort system has been developed based on single-crystal s-CVD diamond sensors. The sensors will be placed in 20 key positions in the vicinity of the interaction region. The severe space limitations require a remote readout of the sensors. In this contribution we present the system design, along with the sensor characterisation procedure. We present also the preliminary results with the prototype system during the first SuperKEKB commissioning phase in February-June 2016.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of flexible, scalable, low cost readout for beam tests of the high granularity calorimeter for the CMS endcap Latest frontier technology and design of the ATLAS calorimeter trigger board dedicated to jet identification for the LHC run 3 The ATLAS tile calorimeter DCS for run 2 The phase-II ATLAS pixel tracker upgrade: Layout and mechanics Null-hypothesis testing using distance metrics for verification of arms-control treaties
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1