{"title":"通过实时智能监控,提高配电馈线的可靠性","authors":"B. Russell, C. Benner, Robert M. Cheney, Charles F. Wallis, Thomas L. Anthony, W. Muston","doi":"10.1109/PES.2009.5275415","DOIUrl":null,"url":null,"abstract":"Feeder reliability has been receiving increased attention. Substantial industry efforts have defined standardized indices for quantifying reliability. Utility commissions and municipalities are requiring utilities to use these indices to identify and make improvements to poorly performing feeders. Reliability indices generally equate to the number and length of outages, and to the number of customers affected. While some outages are unavoidable, others are the result of incipient failures or apparatus malfunction. This paper illustrates how reliability can be improved through real-time situational awareness of faults and events. Emphasis is given to providing actionable information with little or no human intervention. The paper describes how Texas A&M's Distribution Fault Anticipation (DFA) project documented naturally occurring faults and outages on 60 feeders, and examines how those events could be avoided with intelligent monitoring. Reliability improvements are projected through condition-based maintenance and quick response to outages using previously unavailable information on faults and events.","PeriodicalId":258632,"journal":{"name":"2009 IEEE Power & Energy Society General Meeting","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Reliability improvement of distribution feeders through real-time, intelligent monitoring\",\"authors\":\"B. Russell, C. Benner, Robert M. Cheney, Charles F. Wallis, Thomas L. Anthony, W. Muston\",\"doi\":\"10.1109/PES.2009.5275415\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Feeder reliability has been receiving increased attention. Substantial industry efforts have defined standardized indices for quantifying reliability. Utility commissions and municipalities are requiring utilities to use these indices to identify and make improvements to poorly performing feeders. Reliability indices generally equate to the number and length of outages, and to the number of customers affected. While some outages are unavoidable, others are the result of incipient failures or apparatus malfunction. This paper illustrates how reliability can be improved through real-time situational awareness of faults and events. Emphasis is given to providing actionable information with little or no human intervention. The paper describes how Texas A&M's Distribution Fault Anticipation (DFA) project documented naturally occurring faults and outages on 60 feeders, and examines how those events could be avoided with intelligent monitoring. Reliability improvements are projected through condition-based maintenance and quick response to outages using previously unavailable information on faults and events.\",\"PeriodicalId\":258632,\"journal\":{\"name\":\"2009 IEEE Power & Energy Society General Meeting\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE Power & Energy Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PES.2009.5275415\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE Power & Energy Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2009.5275415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

馈线的可靠性已受到越来越多的关注。大量的行业努力定义了量化可靠性的标准化指标。公用事业委员会和市政当局要求公用事业公司使用这些指数来确定并改进表现不佳的馈线。可靠性指数通常等同于停电的次数和长度,以及受影响的客户数量。虽然有些中断是不可避免的,但其他中断是由于早期故障或设备故障造成的。本文阐述了如何通过对故障和事件的实时态势感知来提高可靠性。重点是在很少或没有人为干预的情况下提供可操作的信息。本文描述了德州农工大学的配电故障预测(DFA)项目如何记录60条馈线上自然发生的故障和中断,并研究了如何通过智能监控来避免这些事件。通过基于状态的维护和使用以前无法获得的故障和事件信息对中断的快速响应,预计可靠性将得到提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reliability improvement of distribution feeders through real-time, intelligent monitoring
Feeder reliability has been receiving increased attention. Substantial industry efforts have defined standardized indices for quantifying reliability. Utility commissions and municipalities are requiring utilities to use these indices to identify and make improvements to poorly performing feeders. Reliability indices generally equate to the number and length of outages, and to the number of customers affected. While some outages are unavoidable, others are the result of incipient failures or apparatus malfunction. This paper illustrates how reliability can be improved through real-time situational awareness of faults and events. Emphasis is given to providing actionable information with little or no human intervention. The paper describes how Texas A&M's Distribution Fault Anticipation (DFA) project documented naturally occurring faults and outages on 60 feeders, and examines how those events could be avoided with intelligent monitoring. Reliability improvements are projected through condition-based maintenance and quick response to outages using previously unavailable information on faults and events.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Substation fault analysis requirements On field experience results related to high-impedance faults in power distribution system Reactive power compensation using Z-source based photovoltaic system How can flicker level be determined before a customer is connected to the electric grid Transmission expansion and pricing in Colombia: An appraisal of current practices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1