内置5级级非对称多电平转换器的DVR

S. González, M. Valla
{"title":"内置5级级非对称多电平转换器的DVR","authors":"S. González, M. Valla","doi":"10.1109/ICIT.2013.6505712","DOIUrl":null,"url":null,"abstract":"The power quality (PQ) in distribution systems is principally affected by the pollution introduced by the customers. It is necessary to protect the sensitive loads from disturbances such as sags, swells, source voltage imbalances, etc. The actual solution for this case is to employ a dynamic voltage restorer (DVR) device. The use of multilevel inverters in medium voltage applications is a good solution. In particular, the cascaded asymmetric multilevel converter (CAMC) appears as a very attractive alternative among the 5-level converters for this application. The design of the CAMC as a DVR in a medium voltage distribution power system is presented in this paper. The model and the control strategy are discussed in d-q coordinates synchronous with the source voltage. The performance of the proposed compensator is tested with SPICE simulations.","PeriodicalId":192784,"journal":{"name":"2013 IEEE International Conference on Industrial Technology (ICIT)","volume":"347 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A DVR built with a 5-level cascade asymmetric multilevel converter\",\"authors\":\"S. González, M. Valla\",\"doi\":\"10.1109/ICIT.2013.6505712\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The power quality (PQ) in distribution systems is principally affected by the pollution introduced by the customers. It is necessary to protect the sensitive loads from disturbances such as sags, swells, source voltage imbalances, etc. The actual solution for this case is to employ a dynamic voltage restorer (DVR) device. The use of multilevel inverters in medium voltage applications is a good solution. In particular, the cascaded asymmetric multilevel converter (CAMC) appears as a very attractive alternative among the 5-level converters for this application. The design of the CAMC as a DVR in a medium voltage distribution power system is presented in this paper. The model and the control strategy are discussed in d-q coordinates synchronous with the source voltage. The performance of the proposed compensator is tested with SPICE simulations.\",\"PeriodicalId\":192784,\"journal\":{\"name\":\"2013 IEEE International Conference on Industrial Technology (ICIT)\",\"volume\":\"347 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE International Conference on Industrial Technology (ICIT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIT.2013.6505712\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference on Industrial Technology (ICIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIT.2013.6505712","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

配电系统的电能质量主要受用户引入的污染影响。有必要保护敏感负载免受诸如下垂、膨胀、源电压不平衡等干扰。这种情况的实际解决方案是采用动态电压恢复器(DVR)设备。在中压应用中使用多电平逆变器是一个很好的解决方案。特别是,级联非对称多电平变换器(CAMC)在该应用的5电平变换器中显得非常有吸引力。本文介绍了中压配电系统中作为DVR的CAMC的设计。在与源电压同步的d-q坐标系下讨论了该模型和控制策略。通过SPICE仿真测试了该补偿器的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A DVR built with a 5-level cascade asymmetric multilevel converter
The power quality (PQ) in distribution systems is principally affected by the pollution introduced by the customers. It is necessary to protect the sensitive loads from disturbances such as sags, swells, source voltage imbalances, etc. The actual solution for this case is to employ a dynamic voltage restorer (DVR) device. The use of multilevel inverters in medium voltage applications is a good solution. In particular, the cascaded asymmetric multilevel converter (CAMC) appears as a very attractive alternative among the 5-level converters for this application. The design of the CAMC as a DVR in a medium voltage distribution power system is presented in this paper. The model and the control strategy are discussed in d-q coordinates synchronous with the source voltage. The performance of the proposed compensator is tested with SPICE simulations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Low cost circular couplers for bi-directional IPT systems Performance evaluation of variable rates raptor codes in mobile WiMAX Improved non-ideality compensation for the V/f controlled permanent magnet synchronous motor Overview of helical foil winding design for planar magnetic components Tactile proximity sensors for robotic applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1