{"title":"基于金纳米金字塔的LSPR芯片检测血清心血管标志物蛋白","authors":"Prajna N. D., Tom Devasia, Rajeev K. Sinha","doi":"10.18287/jbpe23.09.030313","DOIUrl":null,"url":null,"abstract":"The localized surface plasmon resonance (LSPR) based technology allows the fabrication of inexpensive biosensors with very simple design for the detection of diseases. In the present work, we systematically fabricated an LSPR sensor chip using Au nanobipyramids (Au NBPs). Au NBPs with longitudinal LSPR band in the near-IR region (~900nm) exhibiting higher refractive index (RI) sensitivity are used for the sensor chip fabrication. The immobilized Au NBPs on a silanized glass coverslip were chemically modified using 11-mercaptoundecanoic acid (11-MUA) and Octanethiol monolayer, followed by activation using EDC-NHS chemistry for the immobilization of the protein molecules. For cardiovascular marker protein detection, monoclonal antibodies were immobilized on the sensor chip, and the marker proteins were detected from the blood serum obtained from the patients. Cardiovascular marker proteins N-terminal pro-B-type natriuretic peptide and cardiac troponin T (CTnT) were successfully detected on the fabricated LSPR sensor chip.","PeriodicalId":52398,"journal":{"name":"Journal of Biomedical Photonics and Engineering","volume":"75 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cardiovascular Marker Proteins Detection in the Blood Serum Using an LSPR Chip Based on Au Nanobipyramid\",\"authors\":\"Prajna N. D., Tom Devasia, Rajeev K. Sinha\",\"doi\":\"10.18287/jbpe23.09.030313\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The localized surface plasmon resonance (LSPR) based technology allows the fabrication of inexpensive biosensors with very simple design for the detection of diseases. In the present work, we systematically fabricated an LSPR sensor chip using Au nanobipyramids (Au NBPs). Au NBPs with longitudinal LSPR band in the near-IR region (~900nm) exhibiting higher refractive index (RI) sensitivity are used for the sensor chip fabrication. The immobilized Au NBPs on a silanized glass coverslip were chemically modified using 11-mercaptoundecanoic acid (11-MUA) and Octanethiol monolayer, followed by activation using EDC-NHS chemistry for the immobilization of the protein molecules. For cardiovascular marker protein detection, monoclonal antibodies were immobilized on the sensor chip, and the marker proteins were detected from the blood serum obtained from the patients. Cardiovascular marker proteins N-terminal pro-B-type natriuretic peptide and cardiac troponin T (CTnT) were successfully detected on the fabricated LSPR sensor chip.\",\"PeriodicalId\":52398,\"journal\":{\"name\":\"Journal of Biomedical Photonics and Engineering\",\"volume\":\"75 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomedical Photonics and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18287/jbpe23.09.030313\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Physics and Astronomy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Photonics and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18287/jbpe23.09.030313","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Physics and Astronomy","Score":null,"Total":0}
引用次数: 0

摘要

基于局部表面等离子体共振(LSPR)的技术允许制造具有非常简单设计的廉价生物传感器,用于检测疾病。在本工作中,我们系统地利用金纳米金字塔(Au nbp)制作了LSPR传感器芯片。在近红外区(~900nm)具有较高折射率(RI)灵敏度的纵向LSPR波段的Au nbp用于传感器芯片的制作。利用11-巯基十四烷酸(11-MUA)和辛烷硫醇单层对固定在硅化玻璃盖上的Au nbp进行化学修饰,然后使用EDC-NHS化学活化以固定蛋白质分子。检测心血管标志物蛋白时,将单克隆抗体固定在传感器芯片上,从患者血清中检测标志物蛋白。在制备的LSPR传感器芯片上成功检测了心血管标志物蛋白n端前b型利钠肽和心肌肌钙蛋白T (CTnT)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Cardiovascular Marker Proteins Detection in the Blood Serum Using an LSPR Chip Based on Au Nanobipyramid
The localized surface plasmon resonance (LSPR) based technology allows the fabrication of inexpensive biosensors with very simple design for the detection of diseases. In the present work, we systematically fabricated an LSPR sensor chip using Au nanobipyramids (Au NBPs). Au NBPs with longitudinal LSPR band in the near-IR region (~900nm) exhibiting higher refractive index (RI) sensitivity are used for the sensor chip fabrication. The immobilized Au NBPs on a silanized glass coverslip were chemically modified using 11-mercaptoundecanoic acid (11-MUA) and Octanethiol monolayer, followed by activation using EDC-NHS chemistry for the immobilization of the protein molecules. For cardiovascular marker protein detection, monoclonal antibodies were immobilized on the sensor chip, and the marker proteins were detected from the blood serum obtained from the patients. Cardiovascular marker proteins N-terminal pro-B-type natriuretic peptide and cardiac troponin T (CTnT) were successfully detected on the fabricated LSPR sensor chip.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Biomedical Photonics and Engineering
Journal of Biomedical Photonics and Engineering Physics and Astronomy-Acoustics and Ultrasonics
CiteScore
1.60
自引率
0.00%
发文量
17
审稿时长
8 weeks
期刊最新文献
Multiparameter Analysis of Statistical Memory Effects in Bioelectric Signals while Performing Cognitive Tasks Potential Thermal Effect of Stimulating Brain Tissue during Low Level Laser Therapy Calculation of the Interference Coefficient of the Polyatomic Molecular Structure of DNA Design of a Photonic Integrated Device with an on-Chip k-Clock and Tunable Reference Arm for Swept-Source Optical Coherence Tomography Spectrometer Design for an 840 nm Spectral Domain Optical Coherence Tomography System
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1