{"title":"新设计的评估职业消防员体能的特定测试的可靠性","authors":"Nemanja Samardžić, Milivoj Dopsaj, Dragan Klisarić","doi":"10.5937/zurbezkrim2301039s","DOIUrl":null,"url":null,"abstract":"The aim of this study was to determine the reliability of newly designed tests for assessing professional firefighters' physical fitness. A total of 15 healthy and physically active firefighters participated in this study. The following tests were performed: Modified Step Test (MStepT), Fire and Rescue Obstacle Course (VPol), Firefighting Equipment Carry Test (NVOpr, and Dummy Drag Test (VLut). The testing was carried out using a randomized method. There was a 10-minute break between the tests. After a week, retesting was conducted under the same conditions. The results of the regression analysis showed that the value of the adjusted coefficient of determination (adjR2 ) for all tests ranged from 0.90 (90.00%) to 0.98 (98.00%), from MStepT to NVOpr respectively, and the repeatability (reliability) of the tests in relation to the sample used in testing for all variables was highly statistically significant (p = 0.000). A moderate effect size (d = 0.748, 95% CI = 0.162 - 1.314) was found for the VPol variable, while the effect size was found small (d = 0.212 - 0.281) for the variables (MStepT, NVOpr, VLut). The findings demonstrated that the examined tests can be applied in the practice of professional firefighters for the purposes of testing physical fitness related to the job. Methodologically, it is acceptable to conduct tests for firefighters in complete PPE so that the test conditions and workload are similar to the situational conditions during intervention in the field.","PeriodicalId":489758,"journal":{"name":"Žurnal za bezbjednost i kriminalistiku","volume":"156 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The reliability of newly designed specific tests for assessing professional firefighters' physical fitness\",\"authors\":\"Nemanja Samardžić, Milivoj Dopsaj, Dragan Klisarić\",\"doi\":\"10.5937/zurbezkrim2301039s\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this study was to determine the reliability of newly designed tests for assessing professional firefighters' physical fitness. A total of 15 healthy and physically active firefighters participated in this study. The following tests were performed: Modified Step Test (MStepT), Fire and Rescue Obstacle Course (VPol), Firefighting Equipment Carry Test (NVOpr, and Dummy Drag Test (VLut). The testing was carried out using a randomized method. There was a 10-minute break between the tests. After a week, retesting was conducted under the same conditions. The results of the regression analysis showed that the value of the adjusted coefficient of determination (adjR2 ) for all tests ranged from 0.90 (90.00%) to 0.98 (98.00%), from MStepT to NVOpr respectively, and the repeatability (reliability) of the tests in relation to the sample used in testing for all variables was highly statistically significant (p = 0.000). A moderate effect size (d = 0.748, 95% CI = 0.162 - 1.314) was found for the VPol variable, while the effect size was found small (d = 0.212 - 0.281) for the variables (MStepT, NVOpr, VLut). The findings demonstrated that the examined tests can be applied in the practice of professional firefighters for the purposes of testing physical fitness related to the job. Methodologically, it is acceptable to conduct tests for firefighters in complete PPE so that the test conditions and workload are similar to the situational conditions during intervention in the field.\",\"PeriodicalId\":489758,\"journal\":{\"name\":\"Žurnal za bezbjednost i kriminalistiku\",\"volume\":\"156 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Žurnal za bezbjednost i kriminalistiku\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5937/zurbezkrim2301039s\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Žurnal za bezbjednost i kriminalistiku","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5937/zurbezkrim2301039s","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是确定新设计的评估专业消防员身体素质的测试的可靠性。共有15名健康且身体活跃的消防员参加了这项研究。进行了以下测试:改进台阶测试(MStepT)、消防和救援障碍测试(VPol)、消防设备携带测试(NVOpr)和假人阻力测试(VLut)。试验采用随机法进行。考试之间有10分钟的休息时间。一周后,在相同的条件下重新进行测试。回归分析结果显示,所有试验的调整后决定系数(adjR2)值分别为0.90(90.00%)~ 0.98(98.00%),从MStepT到NVOpr,测试的重复性(信度)与用于测试的所有变量的样本相关,具有高度统计学意义(p = 0.000)。VPol变量的效应大小适中(d = 0.748, 95% CI = 0.162 - 1.314),而MStepT、NVOpr、VLut变量的效应大小较小(d = 0.212 - 0.281)。研究结果表明,所审查的测试可以应用于专业消防员的实践,以测试与工作相关的身体健康。从方法上讲,在完整的PPE中对消防员进行测试是可以接受的,以便测试条件和工作量与现场干预期间的情景条件相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The reliability of newly designed specific tests for assessing professional firefighters' physical fitness
The aim of this study was to determine the reliability of newly designed tests for assessing professional firefighters' physical fitness. A total of 15 healthy and physically active firefighters participated in this study. The following tests were performed: Modified Step Test (MStepT), Fire and Rescue Obstacle Course (VPol), Firefighting Equipment Carry Test (NVOpr, and Dummy Drag Test (VLut). The testing was carried out using a randomized method. There was a 10-minute break between the tests. After a week, retesting was conducted under the same conditions. The results of the regression analysis showed that the value of the adjusted coefficient of determination (adjR2 ) for all tests ranged from 0.90 (90.00%) to 0.98 (98.00%), from MStepT to NVOpr respectively, and the repeatability (reliability) of the tests in relation to the sample used in testing for all variables was highly statistically significant (p = 0.000). A moderate effect size (d = 0.748, 95% CI = 0.162 - 1.314) was found for the VPol variable, while the effect size was found small (d = 0.212 - 0.281) for the variables (MStepT, NVOpr, VLut). The findings demonstrated that the examined tests can be applied in the practice of professional firefighters for the purposes of testing physical fitness related to the job. Methodologically, it is acceptable to conduct tests for firefighters in complete PPE so that the test conditions and workload are similar to the situational conditions during intervention in the field.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Proxy intelligence and the classification of intelligence actors using the United States as a model The offense of avoidance of withholding tax in the criminal legislation of Serbia The reliability of newly designed specific tests for assessing professional firefighters' physical fitness The importance of forensic entomology in criminal investigations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1